background image

Page 14

Summary of Contents for Gas Fire

Page 1: ...SS 2 FLAME SYSTEM 3 USERS Pages 2 3 INSTALLATION Pages 4 9 AND SERVICING INSTRUCTIONS THIS CAT I2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20 mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER ...

Page 2: ...er the firebox must have a minimum non combustible thickness of 25mm The appliance is fitted with an ODS a spillage monitoring system which operates if the evacuation of products is interrupted i e blocked or incorrect flueing If the gas fire repeatedly goes out it may indicate a problem and the installer or specialist should be informed before further use Areas of this appliance will become hot a...

Page 3: ...leaned off using a non fluffy cloth Laying the Coal Bed The coal support shelf is positioned on the fibre support metalwork ensure that the shelf sits against the two stops which are to prevent the shelf sitting on the burner outlet Place the simulated coal front in position as shown in Fig 6 three tabs are provided to locate The one piece coal support shelf is constructed to allow three levels of...

Page 4: ... 6461 Pt 1 1984 BS 715 1993 BS 1289 Pt 1 1986 BS 7566 Pts 1 4 1992 Technical Data Overall height of fire with spacer 612mm Overall height of fire without spacer 605mm Minimum height of opening required 540mm Maximum height of opening with spacer 590mm Maximum width of opening required 405mm Maximum width of opening with spacer 470mm Forward projection from opening 60mm without front and fret Forwa...

Page 5: ... must not restrict the above listed flues The flue must only service a single appliance and not have any branches or traps that may impede the natural draught Any flue damper plate or restrictor shall be removed or fixed in the fully opened position The front and base of the fire opening must be flat and square to ensure a good seal with the appliance this is to ensure that there is no reduction i...

Page 6: ...he requirements of BS 6891 1988 dealing with enclosed pipes The Standard requires that when a gas pipe is fed through a wall the pipe should be enclosed in a tight sleeve to protect against failure caused by movement It shall be constructed to prevent passage of gas either between the pipe and sleeve or sleeve and wall Where a gas supply pipe enters the box in any of the positions stated the hole ...

Page 7: ...extra thickness to be added where it is necessary to effect a seal on uneven surfaces Remove the backing strip covering the adhesive surface of the strip and position onto the rear of the firebox or the spacer frame where applicable Before offering the vent box into the opening the hearth should be protected from damage or scratches that may occur during installation Locate and secure the vent box...

Page 8: ...fan is situated in the room this test should be repeated with the fan running If there is a connected room with an extractor fan the test should be repeated with all the doors to that room opened and the extractor fan running All smoke must be drawn into the flue If spillage occurs allow a further 10 minutes Should spillage still occur examine the chimney for the fault and rectify Check for satisf...

Page 9: ...xing flange When refitting observe that the two feet at the rear of the assembly locate under the two lugs formed in the base of the box assembly i TO CLEAN OR REPLACE THE INJECTOR Unscrew the compression nut connecting the gas supply to the elbow injector while supporting the injector to prevent distortion of the framework Unscrew and remove the gas supply tube from the gas control valve hold the...

Page 10: ...Page 10 ...

Page 11: ...he surround with the sapcer fitted to satisfy the debris collection requirement Depth B is Nominally 70mm If no chairbrick is fitted the minimum distance required between the rear of the opening and the front face of the surround is 210mm without spacer frame fitted Page 11 ...

Page 12: ...Page 12 ...

Page 13: ...Page 13 ...

Page 14: ...Page 14 ...

Page 15: ...Page 15 ...

Page 16: ...Page 16 ...

Page 17: ...Page 17 ...

Reviews: