3
2.8 Power Connection
Do not cut off or remove three-pin plug.
Plug unit directly into socket and not through an
extension cord.
In case of failure of power supply, please restart the
compressor after five minutes to prevent damage.
Any damage of compressor due to low voltage will
not be included within the warranty range.
3. OPERATION
Recommend: Before storing any food, it is recommended that refrigerator compressor shall be running until the unit gets to
temperature. During this compressor running period, you can check the power wire connection.
3.1 Glass Door Under Counter Chiller
Functions description of keys under normal working condition:
Startup:
Press the power switch button
for 3s.
Shutdown:
Press the power switch button
for 3s.
Set Temp:
Press
for 3s, the setting temp. flashing, and then press
or
to adjust the temperature. After without pressed any key for 6s, it will
return to display working temp. display.
In case demisting function is default as “off”, if you need to turn on the
demisting, you need to change the default demisting setting first.
(1)
Change the default demisting setting:
Press
for 1s and then press
again, display shows PAS, press
to enter password (Its default is
45). If the password is correct, the parameters can be changed, or it just can be viewed. Press
for 1s and display
shows E1, then press
until it shows P1, Press
for 1s to enter into parameter adjustment mode, then the
display shows "01" , means demisting function was default as "off ". Press
for 1s, display shows "00", means the
demisting function can be turn on. Then press
again to exit this mode and it recovers to parameter selection. Waiting
6s to exit, the setting will be remembered.(Above setting only need to set for 1 time, the demising function can be
available, for the following manual demisting, no need setting again.)
(2) When the demisting function is available, press
for 3s then shows
on the display to enter the demisting model.
Press
for 3s again to exit.
Illuminating:
Press
for 1s, the light is on, press the button again, the light will be off. Light automatically turns on
when the door opens.
Manual defrosting:
Press
for 3s, then shows
and enters the defrosting model. Press
for 3s again to exit.
Its factory default value of controlling temperature is -2°C.