Safety precautions
1. Installation, testing, repair or replacement of this product must be done by professional or person sent by dealer.
2. Power supply facilities connected to this product must meet national standards, and all power supply parameters must tally
with this product (See electric parameters chart). Forbid lengthen the power cable.
3. This product must be powered by a RCD with residual current not exceeding 30mA. Besides, for power supply of this
product, an all-pole disconnection power switch meeting requirements must be installed. And regularly confirm that all these
devices are effective.
4. The equipotential (the yellow and green wire) connector of this product must be permanently connected with external
equipotential connector.
5. During installation and application, forbid cutting any of the connecting wires of the product. Do not disassemble the electric
cabinet and control panel. Otherwise, our company will not take any responsibility for product failure, leakage or electric shock
resulted.
6. Acetone, ammonia water, gasoline and such organic solvent and strong acidic chemicals will dissolve and corrode different
parts of this product, so please avoid contacting such substances during installation and application.
7. The product installation area must be well ventilated, dry and without corrosive gassy. If not used for a long time, please cut
off power supply.
8. Before connecting cold and hot water pipes, please discharge the water that has been staying inside the pipes, so as to
prevent damaging water control equipment.
9. Children using this product must be accompanied by an adult. The old and patient should use this product carefully.
Cleaning and maintenance
1. For daily cleaning of the massage bathtub, please use common liquid detergent and soft cloth, but do not use detergent
containing ketone or ammonia water; do not use disinfectant containing formaldehyde for disinfection.
2. Surface stains can be cleaned by rubbing with toothpaste and soft cloth.
3. For slight surface scratches or cigarette burns, please burnish with 2000# levigation sandpaper and then do polishing.
4. For stains on electroplated parts, please wipe slightly with soft lint. Do not use coarse cloth or solvents like thinner.
5. Often clean water suction device to prevent blocking.
6. Irregularly check for inconvenience in use caused by pipe crack or folding.
7. Often check electrical wire, switches, plugs for fall-off or damage, so as to repair in-time.
8. To lengthen service life of the product, please note that continuous use should not exceed 3 hours.
Basic technical parameters
1. Supply voltage: AC190V--240V 50-60Hz
9. Electromagnetic valve: AC12V 8W
2. Water pump power: AC220V 750W
10. Music power: <15W
3. Air pump power: AC220V 750W
11. Frequency range: FM88--108MHz
4. Heater power: AC220V 1500W
12. S/N radio: >45dB
5. Dielectric strength: 1500V 1Min
13. Water proof scale: IPX4
6. Electricity leakage:<0.25mA
7. Ozone: AC 12W 8W
8. Water lamp voltage: AC12V 20W