d)

 

Only the manufacturer's service department can repair the unit. Do not carry 

out repairs yourself! 

e)

 

In case of open flames or fire, use only dry powder or snow (CO2) fire 

extinguishers to extinguish the live equipment. 

f)

 

Check the condition of the safety stickers regularly. Replace them if they are 

illegible.  

g)

 

Keep these instructions for use for future reference. If the unit is to be passed 

on to a third party, the operating instructions must also be handed over 

together with the unit. 

h)

 

Keep the packaging and small assembly parts out of the reach of children. 

i)

 

Keep the unit away from children and animals. 

 

 

Please note! Keep children and other bystanders safe while operating 

the unit. 

 

2.3.

 

 Personal safety 

a)

 

The unit is not intended to be used by persons (including children) with 

reduced mental, sensory or intellectual functions or persons who lack 

experience and/or knowledge unless they are supervised or have been 

instructed by a person responsible for their safety on how to operate the unit. 

b)

 

To prevent accidental start-up, make sure the switch is in the off position 

before connecting to a power source. 

c)

 

The unit is not a toy. Children should be watched to ensure that they do not 

play with the unit. 

d)

 

Do not place your hands or any objects inside the running unit! 

 

2.4.

 

 Safe use of the unit 

a)

 

Do not overload the unit. Use tools that are suitable for the application. A 

correctly selected unit will do a better and safer job for which it was designed. 

b)

 

Do not use the unit if the ON/OFF switch does not function properly (does not 

turn on and off). Units that cannot be controlled by the switch are unsafe, 

cannot operate, and must be repaired. 

c)

 

Disconnect the unit from the power supply before adjusting, cleaning, or 

servicing. This precaution reduces the risk of accidental start-up. 

d)

 

Keep unused equipment out of the reach of children and out of the reach of 

anyone unfamiliar with the unit or this instruction manual. These units is 

dangerous in the hands of inexperienced users. 

e)

 

Keep the unit in good working condition. Check before each use for general 

damage or damage to moving parts (cracks in parts and components or any 

other condition that may affect the safe operation of the unit). If damaged, 

have the unit repaired before use.  

Summary of Contents for RCWI-4G

Page 1: ...expondo com WINE COOLER USER MANUAL Instrukcja obs ugi...

Page 2: ...ktu LOD WKA DO WINA EN Product model RCWI 4G RCWI 6G RCWI 7G PL Model produktu EN Manufacturer expondo Polska sp z o o sp k PL Producent EN Manufacturer Address ul Nowy Kisielin Innowacyjna 7 66 002 Z...

Page 3: ...48 137 Isolating substance Cyclopentane Cooling temperature control range C 5 22 Defrosting function auto Dimensions Width x Depth x Height mm 645 x 630 x 930 643 x 595 x 820 643 x 295 x 821 Weight kg...

Page 4: ...al progress and the possibility of reducing noise into account the unit is designed and built in such a way so that risks resulting from noise emissions are reduced to the lowest possible level Explan...

Page 5: ...the socket Keep the cord away from heat sources oil sharp edges or moving parts Damaged or tangled cords increase the risk of electric shock e If you cannot avoid using the unit in a wet environment...

Page 6: ...l start up make sure the switch is in the off position before connecting to a power source c The unit is not a toy Children should be watched to ensure that they do not play with the unit d Do not pla...

Page 7: ...t heaters boilers and do not install the unit in direct sunlight s Do not damage the refrigerant circuit t Do not allow the rear coils of the unit to come into contact with the wall surface u CAUTION...

Page 8: ...ed to be safe with adequate safeguards and despite the additional safety features provided to the user there is still a slight risk of accident or injury when handling the unit You are advised to use...

Page 9: ...panel model RCWI 6G RCWI 7G 8 Cooling chamber 9 Hopper a Power switch b LED chamber lighting button c Temperature regulation button d Button for regulation increasing value e Button for adjusting decr...

Page 10: ...but it is possible to install the door as a left hand door according to the user s preference The unit is designed for free standing or built in operation a CAUTION Before proceeding to the removal i...

Page 11: ...bracket and the door q Pass the previously prepared mounting structure through the top and bottom mounting holes Press the mounts together r Reinstall the gasket at the dedicated location s In order...

Page 12: ......

Page 13: ...Once the system reaches the set threshold value the unit panels will gradually cool down until the temperature value around the unit is reached MODEL RCWI 4G a The unit is started using the control p...

Page 14: ...ating temperature units from the control panel select and hold the refrigeration compartment LED light button c for about 5 seconds i The temperature unit F C of the unit s operation is displayed by t...

Page 15: ...he control panel Selecting the button again will turn off the chamber illumination c The unit is equipped with a system for maintaining the optimal humidity level inside the refrigeration compartment...

Page 16: ...out the mains plug before each cleaning and when the unit is not in use b Only mild detergents designed for cleaning food contact surfaces may be used to clean the unit c After each cleaning all the...

Page 17: ...OF USED UNITS At the end of its useful life this product should not be disposed of with normal household waste but should be taken to a collection point for the recycling of electrical and electronic...

Page 18: ...r is tight closed properly Failure in power supply of the unit Reconnect the unit and wait a minimum of 4 hours for the cooling temperature to stabilize Cooling chamber temperature too low Incorrectly...

Page 19: ...re on the outer panel of the unit door Unit door ajar contact with temperature difference between cooled air inside the chamber and room temperature air from outside the unit Check that the door is ti...

Page 20: ...20 Klasa klimatyczna N SN ST N ST Klasa efektywno ci energetycznej G Zu ycie energii kWh 24h 0 400 0 405 0 375 Roczne zu ycie energii kWh rok 146 148 137 Substancja izoluj ca Cyklopentan Zakres regula...

Page 21: ...Dane techniczne i specyfikacje zawarte w tej instrukcji obs ugi s aktualne Producent zastrzega sobie prawo dokonywania zmian zwi zanych z podwy szeniem jako ci Uwzgl dniaj c post p techniczny i mo li...

Page 22: ...gotnym otoczeniu Przedostanie si wody do urz dzenia zwi ksza ryzyko jego uszkodzenia oraz pora enia pr dem c Nie wolno dotyka urz dzenia mokrymi lub wilgotnymi r koma d Nie nale y u ywa przewodu w spo...

Page 23: ...rukcj u ytkowania w celu jej p niejszego u ycia W razie gdyby urz dzenie mia o zosta przekazane osobom trzecim to wraz z nim nale y przekaza r wnie instrukcj u ytkowania h Elementy opakowania oraz dro...

Page 24: ...uszkodzenia odda urz dzenie do naprawy przed u yciem f Naprawa oraz konserwacja urz dze powinna by wykonywana przez wykwalifikowane osoby przy u yciu wy cznie oryginalnych cz ci zamiennych Zapewni to...

Page 25: ...y Urz dzenie nie jest przeznaczone do zamra ania produkt w spo ywczych z P ki ustawione fabrycznie zapewniaj najbardziej efektywne wykorzystanie energii przez urz dzenia ch odnicze aa Nie wolno u ywa...

Page 26: ...dzenie przeznaczone jest do przechowywania napoi w naczyniach zewn trznych przy zastosowaniu odpowiedniej temperatury Obszar u ytkowania obejmuje wy cznie gospodarstwa domowe i ich pochodne Odpowiedz...

Page 27: ...model RCWI 6G RCWI 7G 8 Komora ch odnicza 9 Zbiornik a Prze cznik zasilania b Przycisk o wietlenia LED komory c Przycisk regulacji temperatury d Przycisk regulacji zwi kszania warto ci e Przycisk reg...

Page 28: ...enie mo e generowa charakterystyczny zapach kt ry stopniowo b dzie ulatnia si wraz z osi ganiem przez urz dzenie zaprogramowanej temperatury MONTA URZ DZENIA Urz dzenie fabrycznie posiada konfiguracj...

Page 29: ...lokuj c a nast pnie podk adk p ask p Przy o y uchwyt urz dzenia od strony zewn trznej drzwi Zr wna osie otwor w monta owych uchwytu i drzwi q Uprzednio przygotowan konstrukcj mocowania przeprowadzi pr...

Page 30: ......

Page 31: ...dzenia wysokich temperatur Po osi gni ciu przez system zadanej warto ci progowej panele urz dzenia b d stopniowo sch adza si a do osi gni cia warto ci temperatury panuj cej wok urz dzenia MODEL RCWI 4...

Page 32: ...terowania wybra i przytrzyma przez oko o 5 sekund przycisk o wietlenia LED komory ch odniczej c i Jednostka temperatury F C pracy urz dzenia wy wietlana jest za pomoc wska nika LED na panelu sterowani...

Page 33: ...przycisk o wietlenia LED b Ponowne wybranie przycisku wy czy pod wietlenie komory c Urz dzenie wyposa ono w system utrzymywania optymalnego poziomu wilgotno ci wewn trz komory ch odniczej Zbiornik 9 r...

Page 34: ...nie powinny dotyka panelu przedniego ani tylnego Nale y zachowa odpowiedni odst p mi dzy wsadem a domkni tymi drzwiami oraz tyln cian urz dzenia 3 4 Czyszczenie i konserwacja a Przed ka dym czyszczen...

Page 35: ...roces odszraniania komory ch odniczej przebiega automatycznie i nie wymaga dodatkowych dzia a przez u ytkownika Nale y pami ta o okresowym oczyszczaniu tacy odparowania oraz otworu odp ywowego wody ro...

Page 36: ...ostawienie uchylonych drzwi na d u szy czas Kontrolowa cz stotliwo i czas uchylania drzwi Niedomkni te drzwi urz dzenia Sprawdzi poprawno szczelno ci domkni cia drzwi Awaria w zasilaniu dostawie pr du...

Page 37: ...czas uchylania drzwi Brak prawid owego domkni cia drzwi Sprawdzi poprawno szczelno ci domkni cia drzwi Wyst powanie wilgoci na zewn trznym panelu drzwi urz dzenia Uchylone drzwi urz dzenia zetkni cie...

Page 38: ...Frequen cy Current Energy consump tion Refrigera nt Volume Weight Producti on Year Serial No Manufact urer PL Model Klasa klimatycz na Klasa ochronn o ci Napi cie Cz stotli wo Pr d znamion owy Zu ycie...

Page 39: ...ich ber Ihren lokalen Abfallkalender oder bei Ihrer Stadt oder Gemeindeverwaltung ber die in Ihrem Gebiet zur Verf gung stehenden M glichkeiten der R ckgabe oder Sammlung von Altger ten 1 RICHTLINIE 2...