the device is located is
below 7
o
C.
to one with a higher
temperature.
The device does
not work
("ICE FULL" and
"FAULT" lights
are on)
a)
Broken or not
connected sensor (or
broken circuit) for the
ice container being
full.
a)
Check the connection
and the sensor - if
damaged, replace it.
The device does
not work
(the "FAULT"
light blinks)
a)
Condenser sensor
defective or not
connected (or broken
circuit).
a)
Check the connection
and the sensor - if
damaged, replace it.
The "WATER
LOW" and "ICE
FULL" indicators
blink together
or the "FAULT"
lamp flashes
quickly.
a)
Refrigerant leakage.
b)
Compressor is not
working.
c)
The ambient
temperature of the
environment is below
7
o
C.
a)
Locate the leak and seal
the system and fill it up
with the refrigerant.
b)
Damaged compressor
or ambient
temperature exceeds
38
o
C.
c)
Wait until the ambient
temperature rises or
change the place of
operation of the device
to one with a higher
temperature.
The "FAULT",
"WATER LOW"
and "ICE FULL"
lights flash
slowly.
a)
The Hall sensor is not
attached properly or is
damaged.
b)
Fan motor damaged.
a)
Check its installation
and, if necessary,
correct it or replace it
with a new one.
b)
Replace the fan motor.
After some time
of operation,
the "FAULT"
light flashes
quickly
a)
Ice agitator motor
damaged.
b)
Defective
microswitches.
c)
Damaged water
container.
d)
Water container
blocked by ice lumps.
a)
Replace with a new
one.
b)
Check installation or
replace.
c)
Replace with a new
one.
d)
Remove the ice cubes
from the container.
The unit stops
working after 2
or more
minutes
a)
No water in the
running water supply.
b)
Water inlet valve
broken or not
connected.
a)
Check the running
water supply.
b)
Check the valve
connection or replace
it.