31/44
Thermal fuse
A thermal fuse is provided as an extra safety precaution. If this triggers and opens
the electric circuit, the cause of this is an abnormal overheating in the appliance.
In this case, the appliance must be repaired by a specialist to ensure continued
safe heating. Please contact the ROWI Service Team to replace defective parts
and install a new fuse.
Anti-tipping protection
The anti-tipping protection is triggered as soon as the appliance exceeds a definite
angle of inclination. At the same time, the appliance switches off automatically. To
start operating the appliance again, this must be in a vertical position.
1.5 Technical data
Power supply
220-240 V~50 Hz
Heat output
2000 W
Heating stages
2 stage (1000 W/2000 W)
Room heating capacity
(assuming a room height of 2.4 m)
approx. 60 m³
Protection class
II
Degree of protection
IPX0
Setup dimensions (W x D x H)
21.0 x 23.5 x 55.0 cm
Product weight
3.1 kg
Tab. 1: Technical data
1.6 Prohibited areas of application
P
The appliance may only be used indoors.
P
This appliance may not come into contact with water or moisture either during
operation or during storage.
P
This appliance is only designed for household use. Do not use this appliance
for commercial purposes.
P
The appliance may not be used for ceiling installation.
GB