Step 5
IMPORTANT: Overwritten settings.
By adding the device to RMS via the RMS-CONVERTER, the following configuration will be
overwritten on the device:
Fix value humidity: disabled
Fix value temperature: disabled
Fix value if no probe is connected: disabled
Default relative humidity unit: %rh
Default temperature unit: °C
Note: if one of the settings above is changed with HW4 further to the initial installation
into RMS, then RMS will not note the change. However, such a change would cause RMS
to not work correctly. The changes will however be overwritten should the RMS-
CONVERTER reboot (due to a short power interrupt).
Step 6
Finish configuration.