16.0 Periodic Maintenance
PM-LP-006b
Page: 1/10
Component:
Single-acting actuator
Task:
LP type 1 and type 2 pneumatic cylinder seals replacement
Equipment, Tools, Materials:
Spare seals
Wrench
Lifting clump
Lifting tools
Project documentation
Warnings:
Description:
Note: the following instructions apply to single-acting actuator unless otherwise specified.
Cut-off power supply and electric power supply (if present) before performing any operation.
Adequate lifting devices and suitable for the weight must be applied by skilled personnel.
Preliminary actions
1. Remove actuator from valve and remove all couplings as well (see Removal from Valve, page 11)
2. Position the actuator on a workbench (if possible) or in a stable position and in a clean and closed area
3. Remove any control equipment (if present). Refer to the project specific documentation
4. Remove pneumatic pipes
APPLICABLE TO TYPE 0 WITH STOP BOLT ONLY (5)
5. Remove cap nut (1) and O-ring (2)
6. Measure length (W)
W
1
2
7. Hold stop bolt (3) with a wrench and loosen and remove
stop nut (4)
8. Remove O-ring (5)
4
5
3
A4