Rotor Vitamat INOX
CH-3661 Uetendorf
Grossküchen- und Bäckereimaschinen
© Rotor Lips AG
16
Instruction Manual
4. TECHNICAL DATA
Power supply:
230-240 V/4,8 A or 120 V/ 7,2 A, +/- 6%, 48...62 Hz,
sinusoidal, interference free
Power requirement: more than 1 500 W / 2 HP peak
Filler opening:
ø80 mm with inset for halved feed shoot (semi-circular)
Protection: IP34
Motor:
High temperature resistant collector motor with fan and mechanical break
Speed:
Control range 1= 5 000 rpm, 2= 5 600 rpm electronically controlled,
smooth gradient starting
Electrical equipment: - the motor has a thermal protection and is electronically monitored
- Protection class I (according to EN 60335-1)
- electromagnetically shielded
Construction:
- motor base, lid, collecting bowl, centrifugal basket
and grating disc in stainless steel
- plunger is constructed of impact resistant hard-polyethylene (PE-HD)
Weight:
16,5 kg net
Noise emissions:
65 dBA (LpA according to standard EN 12852)
Temperaturerang: operating: 10...40°C
storage: -20...70°C
Humidity:
operating:
0...80% non condensing
storage:
0...95% non condensing
Altitude:
0...2 000 m. (0...6 600 ft)
We reserve the right to make technical changes at any time