89
GB
Trade mark
Rotheigner Air Pressure 100/125/150/200
Model
Ø 100
Ø 125
Ø 150
Ø 200
Climate zone (Cold, Average, Warm) C A W C A W C A W C A W
kWh/(m
2•
a)
-53 -26 -10 -53 -26 -11 -54 -27 -11 -54 -27 -11
AHS annual heating saved, kWh/(m²a) 55 28 13 55 28 13 55 28 13 55 28 13
Specific energy consumption
A+ C
E A+ C
E A+ B
E A+ C
E
Type of ventilation unit
Unidirectional
Type of drive installed
Variable speed drive
Type of heat recovery system
none
Thermal efficiency of heat recovery
not applicable
Maximum flow rate
225 m
3
/h
300 m
3
/h
400 m
3
/h
700 m
3
/h
Electric power input
80 W
80 W
80 W
107 W
Sound power level
66 dB(A)
66 dB(A)
66 dB(A)
68 dB(A)
Reference flow rate
0,044 m
3
/s 0,058 m
3
/s 0,078 m
3
/s 0,136 m
3
/s
Reference pressure difference
50 Pa
50 Pa
50 Pa
50 Pa
Specific power input (SPI) W/(m
3
/h)
0,197
0,167
0,129
0,112
Control typology
Local demand control
Max. internal/external leakage rate
2,70 %
Mixing rate of non-ducted ventilation
not applicable
Visual filter change warning
not applicable
Regulated exhaust grill installation
recommended
Internet address:
www.hornbach.com
Airflow sensitivity to pressure variations
not applicable
Indoor/outdoor air tightness
not applicable
Annual electricity consumption AEC, kWh/(m²a) 2
2
1
1