background image

4 Operation

User reference guide

12

RGSQH10S18AA9W

ROTEX HPU ground

4P374247-1 – 2014.03

During period…

You can read out…

A1

The next scheduled action (

a

)

A2

The active action (

a

)

B1

The next scheduled action (

b

)

B2

The active action (

b

)

2

Press 

 or 

 to overrule. 

Note: 

If the desired temperature is

weather dependent, you cannot change it on the home page.

Usage example: You need more hot water than scheduled

If you are in the following situation:

Current time = 10:30

Next scheduled action of the DHW tank = Heat up to the preset
value (Eco; example: 55°C and sufficient for 2 persons) at 14:00

This evening you need hot water for 3 persons

Then you can do the following:

1

Go to the DHW tank temperature home page (Tank).

2

Overrule the next scheduled action by doing one of the
following:

Change from 55°C to 60°C (when defining hot water as
temperature)

Change from 2 persons to 3 persons (when defining hot
water as number of persons)

Advantages:

You will have sufficient hot water (= comfortable).

You do NOT have to change the schedule (= easy).

You do NOT have to activate the DHW tank booster mode (=
 energy saving).

4.5.6

Using the DHW tank booster mode

About the DHW tank booster mode

You can use the DHW tank booster mode to immediately start
heating up the water to the preset value (Storage comfort). However,
this consumes extra energy.

To check if the DHW tank booster mode is active

1

Go to the DHW tank temperature home page (Tank).

2

Check the following:

In user profile = Basic: If   is displayed, the DHW tank
booster mode is active.

In user profile = Detailed: If   is selected, the DHW tank
booster mode is active.

To activate the DHW tank booster mode (method 1)

1

Go to the DHW tank temperature home page (Tank).

2

Press 

 for more than 5 seconds.

To activate the DHW tank booster mode (method 2)

Prerequisite: 

User profile = Detailed

1

Go to the DHW tank temperature home page (Tank).

2

Press 

 to select  .

Usage example: You immediately need more hot water

If you are in the following situation:

You already consumed most of your hot water.

You cannot wait for the next scheduled action to heat up the
DHW tank.

Then you can activate the DHW tank booster mode.

Advantage: The DHW tank immediately starts heating up the water
to the preset value (Storage comfort).

4.6

Advanced usage

4.6.1

Using quiet mode

INFORMATION

Quiet mode is NOT applicable for this unit.

4.6.2

Using holiday mode

About holiday mode

During your holiday, you can use the holiday mode to deviate from
your normal schedules without having to change them. You can only
use holiday mode if temperature control = room thermostat control.
See also 

"4.4.3 Controlling the temperature" on page 6

.

Using holiday mode typically consists of the following stages:
1

Configuring the holiday for one of the following situations:

2

Activating the holiday mode.

If you do NOT activate, the configured holiday settings will
NOT be used.

If you activate:

Period

Then…

Before and after your
holiday

Your normal schedules will be used.

During your holiday

The configured holiday settings will
be used.

To check if holiday mode is activated and/or running

1

Press 

 to go to one of the home pages.

2

Check the following:

If… is displayed

Then…

One of the following holiday
modes is activated:

Holiday mode (Away) is
activated, but NOT running
yet.

Holiday mode (Home) is
activated. You cannot see if
the holiday mode is already
running.

0RQ

+ROLGD\

8QWLO
$FWXDOWHPS

)HE

r&

Holiday mode (Away) is
activated and running.

To configure the holiday (when you stay at home)

1

Go to [2.2]: 

 > Holiday > Holiday mode.

2

Select Home.

3

Configure the holiday mode settings (when you stay at home).

4

Activate the holiday mode.

Possible holiday mode settings (when you stay at home)

Setting

Description

From and Until

First and last day of your holiday.

Use day
schedule 

Day schedule used during your holiday.

Example: 

Saturday

Summary of Contents for HPU ground

Page 1: ...User reference guide ROTEX HPU ground English User reference guide ROTEX HPU ground RGSQH10S18AA9W...

Page 2: ...g tips 18 6 Maintenance and service 19 6 1 Overview Maintenance and service 19 6 2 To find the contact helpdesk number 19 7 Troubleshooting 19 7 1 Overview Troubleshooting 19 7 2 To check the error hi...

Page 3: ...our system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is...

Page 4: ...at a glance 4 2 1 Buttons a e f b d c a HOME PAGES Switches between home pages when you are on a home page Goes to the default home page when you are in the menu structure b MALFUNCTION INFORMATION I...

Page 5: ...ges You can use the home pages to read out and change settings that are meant for daily usage What you can see and do on the home pages is described where applicable Depending on your system layout th...

Page 6: ...temperature Leaving water temperature control External room thermostat control To determine which temperature control you are using method 1 Check the installer settings table filled in by the instal...

Page 7: ...re See also Using the leaving water temperature home pages main additional on page 9 4 7 Preset values and schedules on page 14 Leaving water temperature control Leaving water temperature control mean...

Page 8: ...2 hours If you temporarily overrule the schedule by a preset value after 2 hours the schedule will be used again If user profile Basic then you can temporarily overrule the room temperature schedule...

Page 9: ...ving water temperature than radiators and heat pump convectors and or fan coil units You only have to adjust leaving water temperature settings in case of problems Typical leaving water temperature ho...

Page 10: ...ust the reheat temperature Condition is displayed on the DHW tank temperature home page Activate the DHW tank booster mode You can Location Only for field supplied domestic hot water pump for secondar...

Page 11: ...6 0A 6 0C 6 08 6 08 Tt DHW tank temperature t Time 6 0A Storage comfort 6 0B Storage eco 6 0C Reheat 6 08 Reheat hysteresis In scheduled reheat mode you can do the following You can Location Do the sa...

Page 12: ...etailed 1 Go to the DHW tank temperature home page Tank 2 Press to select Usage example You immediately need more hot water If you are in the following situation You already consumed most of your hot...

Page 13: ...ain activate the holiday mode again Advantage You do NOT have to change your schedule or holiday configuration 4 6 3 Reading out information About reading out information The amount of information you...

Page 14: ...n to prevent people from changing its settings Possible function locks To check if locking is active 1 Press to go to one of the home pages 2 If is displayed child lock is active Note If you are on a...

Page 15: ...ant to use a schedule Example 5 1 1 Heating 4 Select a predefined or user defined schedule and press To program a schedule 1 Go to 7 3 User settings Set schedules 2 Open an empty predefined or user de...

Page 16: ...edefined 2 Mon Fri 07 00 09 00 17 00 12 00 23 00 14 00 Sat Sun 23 00 08 00 Predefined 3 Mon Sun 23 00 08 00 4 7 5 Predefined schedules Leaving water temperature additional Additional zone On Additiona...

Page 17: ...O QIRUPDWLRQ FWXDWRUV 2SHUDWLRQ PRGHV 5XQQLQJ KRXUV 9HUVLRQ LVSOD Temperature lock 6HW VFKHGXOHV 3UHVHW YDOXHV 8VHU VHWWLQJV OORZHG RSHUDWLRQ PRGH 8QLW RI PHDVXUHPHQW ROLGD Holiday mode URP 8QWLO ROLG...

Page 18: ...emergency If the house is unattended for longer periods we recommend that setting A 5 1 2 Auto emergency operation shall be set to Automatic 4 9 2 Space heating control Setting Default Fill in Leavin...

Page 19: ...greenhouse gases covered by the Kyoto Protocol Do NOT vent gases into the atmosphere Refrigerant type R410A Global warming potential value 1975 Periodical inspections for refrigerant leaks may be requ...

Page 20: ...of your system user interface indoor unit outdoor unit DHW tank contact your installer You can find the contact helpdesk number via the user interface 10 Glossary DHW Domestic hot water Hot water used...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...68280 Sundhoffen Tel 33 0 3 89 21 74 70 Fax 33 0 3 89 21 74 74 e mail info rotex fr www rotex fr DAIKIN AIRCONDITIONING BELGIUM NV A v e n u e F r a n k l i n 1 B B 1 3 0 0 W a v r e Tel 32 0 10 23 7...

Reviews: