background image

4 Operation

User reference guide

11

RGSQH10S18AA9W
ROTEX HPU ground
4P374247-1 – 2014.03

In scheduled mode, you can do the following:

You can…

Location

Read out

 the active or next scheduled desired

temperature.

DHW tank
temperature
home page

Overrule

 the active or next scheduled desired

temperature

.

Condition:   is displayed on the DHW tank
temperature home page.

Activate 

the DHW tank

 booster mode.

Select

 a DHW tank temperature 

schedule

.

Menu structure

Program

 a DHW tank temperature 

schedule

.

Define preset values

 that are used by the

DHW tank temperature schedule.

(Only for field supplied domestic hot water
pump for secondary return)

Program a domestic hot water pump schedule

to determine when to turn ON and OFF the pump.

When turned ON, the pump runs and makes sure
hot water is instantly available at the tap. To save
energy, only turn ON the pump during periods of
the day when instant hot water is necessary.

See also:

"4.5.5 Using the DHW tank temperature home page" on page 11

"4.5.6 Using the DHW tank booster mode" on page 12

"4.7 Preset values and schedules" on page 14

4.5.4

Sch reheat mode

In sch reheat mode (   ), the domestic hot water control is
the same as in scheduled mode. However, when the DHW tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis value = [6-0C]–[6-08]; example: 35°C), the DHW tank
heats up until it reaches the reheat set point ([6-0C]; example: 45°C).
This ensures that a minimum amount of hot water is available at all
times.

Example: 

t

Tt

60°C

00:00

07:00

50°C

45°C

15°C

14:00

21:00

35°C

1

2

4

5

3

[6-0C]=

[6-0B]=

[6-0A]=

[6-0C]–[6-08]=

[6-08]

T

t

DHW tank temperature

t

Time

[6-0A]

Storage comfort

[6-0B]

Storage eco

[6-0C]

Reheat

[6-08]

Reheat hysteresis

In sch reheat mode, you can do the following:

You can…

Location

Do the same things as in scheduled mode.

Adjust the preset value

 (Reheat).

Menu structure

See also:

"4.5.3 Scheduled mode" on page 10

"4.7 Preset values and schedules" on page 14

4.5.5

Using the DHW tank temperature home
page

Typical DHW tank temperature home pages

Depending on the user profile, the user interface gives you either a
basic or a detailed home page. Depending on an installer setting,
either an actual temperature or a number of people is displayed to
indicate the domestic hot water tank temperature. The examples in
the illustrations below are in DHW tank mode = Scheduled.

User profile = Basic

User profile = Detailed

0RQ

7DQN

'HVLUHGWHPSHUDWXUH

r&

0RQ

7DQN

6WRUDJHFRPIRUW

r&

7XH

0RQ

7DQN

'HVLUHGWHPSHUDWXUH

0RQ

7DQN

6WRUDJHFRPIRUW

7XH

Depending on an installer setting, you have to define how much hot
water you want differently:

If you see…

Then you have to define…

r&

To which temperature the
DHW tank has to heat up.

For how many people you need
hot water. The software then
automatically calculates the
corresponding DHW tank
temperature based on installer
settings.

To read out and adjust the desired reheat temperature (in
scheduled and reheat mode)

1

Go to [7.4.3.3]: 

 > User settings > Preset values > Tank

temperature > Reheat.

Result: 

You can read out the desired reheat temperature. 

2

Press 

 or 

 to adjust.

To read out and overrule the active or next scheduled desired
temperature (in scheduled mode or sch reheat mode)

1

Go to the DHW tank temperature home page (Tank).

Result: 

r&

 or 

 is displayed.

t

a

b

Tt

A1 A2

B1

B2

A1

A1 A2

B1

B2

A1

T

t

DHW tank temperature

t

Time

Summary of Contents for HPU ground

Page 1: ...User reference guide ROTEX HPU ground English User reference guide ROTEX HPU ground RGSQH10S18AA9W...

Page 2: ...g tips 18 6 Maintenance and service 19 6 1 Overview Maintenance and service 19 6 2 To find the contact helpdesk number 19 7 Troubleshooting 19 7 1 Overview Troubleshooting 19 7 2 To check the error hi...

Page 3: ...our system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is...

Page 4: ...at a glance 4 2 1 Buttons a e f b d c a HOME PAGES Switches between home pages when you are on a home page Goes to the default home page when you are in the menu structure b MALFUNCTION INFORMATION I...

Page 5: ...ges You can use the home pages to read out and change settings that are meant for daily usage What you can see and do on the home pages is described where applicable Depending on your system layout th...

Page 6: ...temperature Leaving water temperature control External room thermostat control To determine which temperature control you are using method 1 Check the installer settings table filled in by the instal...

Page 7: ...re See also Using the leaving water temperature home pages main additional on page 9 4 7 Preset values and schedules on page 14 Leaving water temperature control Leaving water temperature control mean...

Page 8: ...2 hours If you temporarily overrule the schedule by a preset value after 2 hours the schedule will be used again If user profile Basic then you can temporarily overrule the room temperature schedule...

Page 9: ...ving water temperature than radiators and heat pump convectors and or fan coil units You only have to adjust leaving water temperature settings in case of problems Typical leaving water temperature ho...

Page 10: ...ust the reheat temperature Condition is displayed on the DHW tank temperature home page Activate the DHW tank booster mode You can Location Only for field supplied domestic hot water pump for secondar...

Page 11: ...6 0A 6 0C 6 08 6 08 Tt DHW tank temperature t Time 6 0A Storage comfort 6 0B Storage eco 6 0C Reheat 6 08 Reheat hysteresis In scheduled reheat mode you can do the following You can Location Do the sa...

Page 12: ...etailed 1 Go to the DHW tank temperature home page Tank 2 Press to select Usage example You immediately need more hot water If you are in the following situation You already consumed most of your hot...

Page 13: ...ain activate the holiday mode again Advantage You do NOT have to change your schedule or holiday configuration 4 6 3 Reading out information About reading out information The amount of information you...

Page 14: ...n to prevent people from changing its settings Possible function locks To check if locking is active 1 Press to go to one of the home pages 2 If is displayed child lock is active Note If you are on a...

Page 15: ...ant to use a schedule Example 5 1 1 Heating 4 Select a predefined or user defined schedule and press To program a schedule 1 Go to 7 3 User settings Set schedules 2 Open an empty predefined or user de...

Page 16: ...edefined 2 Mon Fri 07 00 09 00 17 00 12 00 23 00 14 00 Sat Sun 23 00 08 00 Predefined 3 Mon Sun 23 00 08 00 4 7 5 Predefined schedules Leaving water temperature additional Additional zone On Additiona...

Page 17: ...O QIRUPDWLRQ FWXDWRUV 2SHUDWLRQ PRGHV 5XQQLQJ KRXUV 9HUVLRQ LVSOD Temperature lock 6HW VFKHGXOHV 3UHVHW YDOXHV 8VHU VHWWLQJV OORZHG RSHUDWLRQ PRGH 8QLW RI PHDVXUHPHQW ROLGD Holiday mode URP 8QWLO ROLG...

Page 18: ...emergency If the house is unattended for longer periods we recommend that setting A 5 1 2 Auto emergency operation shall be set to Automatic 4 9 2 Space heating control Setting Default Fill in Leavin...

Page 19: ...greenhouse gases covered by the Kyoto Protocol Do NOT vent gases into the atmosphere Refrigerant type R410A Global warming potential value 1975 Periodical inspections for refrigerant leaks may be requ...

Page 20: ...of your system user interface indoor unit outdoor unit DHW tank contact your installer You can find the contact helpdesk number via the user interface 10 Glossary DHW Domestic hot water Hot water used...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...68280 Sundhoffen Tel 33 0 3 89 21 74 70 Fax 33 0 3 89 21 74 74 e mail info rotex fr www rotex fr DAIKIN AIRCONDITIONING BELGIUM NV A v e n u e F r a n k l i n 1 B B 1 3 0 0 W a v r e Tel 32 0 10 23 7...

Reviews: