RKRTR + EKRTETS
Room thermostat
4PW56107-1
Installation manual
8
3.3.
Installation of the receiver
The receiver needs to be installed indoors, typically close to the
unit.
Recommendations for an optimum signal
reception
Take the installation suggestions for the receiver into account
when selecting the installation location and follow the
recommendations below.
■
Do not install the receiver inside a metal box.
■
Mount the receiver vertically, and minimum 10 cm away
from the unit.
■
Mount the receiver minimum 10 cm away from any vertical
metal pipe or vertical electric circuit.
■
Mount the receiver at least 1.5 m above the ground.
Before obtaining access to terminals, all power
supply circuits must be interrupted.