1. TECHNICAL SPECIFICATION

Model

I31W

CADR

m

3

/h

310

Dimension (W×D×H)

mm

450×298×616

Weight

kg

7,8

Rated Power

W

55

Rated Voltage

V-Hz

220-240~50

Coverage Area

m

2

10-70

Noise

dB(A)

62

2. PRODUCT STRUCTURE

1.  Operation Buttons
2.  Display Screen
3.  The Outlet
4.  Right Side Handle
5.  Back Panel Cover
6.  Water Tank
7.  Front Panel Cover
8.  Left Side Handle
9.  Sensor

2

1

3

8

9

4

5

6

7

Pic. 2

Pic. 1

Summary of Contents for I31W

Page 1: ...ENG User manual IONE W I31W ...

Page 2: ...RT 2 INTRODUCTION 6 Technical Specification 6 Product structure 6 PART 3 TECHNOLOGY 7 Purification Process 7 PART 4 OPERATION INSTRUCTIONS 8 Control panel and operation 8 PART 5 FILTER AND WATER TANK REPLACEMENT 9 Filter replacement 9 The humidifier function 9 PART 6 CLEAN AND MAINTENANCE 10 Clean the machine 10 PART 7 ELECTRICAL SCHEMATIC DIAGRAM 11 PART 8 TROUBLESHOOTING 12 ...

Page 3: ...on you can pass the device without the cost B When you buy a new device the seller will accept the old device without any fees C Manufacturer will take the product from buyer produkt without charging it with costs D Products of this type contains valuable elements it can be sold sprzedane on purchase of metals Throwing the device on wild exposes you to the risk of losing your health Dangerous subs...

Page 4: ...take off power plug do not let the detective product working 5 This product can only be repaired by authorized repairing center If maintenance in non authorized repair center it is easily lead to other unsafe factors 6 If the power cable damaged in order to avoid danger must be replaced by the manufacturer or others professionals Any content with this symbol is prohibited Otherwise the product may...

Page 5: ...ll damage the surface of the machine Only use a soft cloth to clean the surface of the machine otherwise the unit may be damaged or cracked When using this unit do not get near or placed on heat sources such as a fireplace or a heater or a place where it may come into contact with flammable gases Remove dust from the power plug periodically Only use 220V standard socket Do not use an air purifier ...

Page 6: ... D H mm 450 298 616 Weight kg 7 8 Rated Power W 55 Rated Voltage V Hz 220 240 50 Coverage Area m2 10 70 Noise dB A 62 2 PRODUCT STRUCTURE 1 Operation Buttons 2 Display Screen 3 The Outlet 4 Right Side Handle 5 Back Panel Cover 6 Water Tank 7 Front Panel Cover 8 Left Side Handle 9 Sensor 2 1 3 8 9 4 5 6 7 Pic 2 Pic 1 ...

Page 7: ...tes particles as small as 0 3 microns with a precision of 99 It helps eliminate dust bacteria fungi viruses allergens and all tiny particles from penetrating through 3 Activated carbon filter layer The Activated carbon filter layer can effectively remove formaldehyde benzene xylene TVOC smoke and garbage odours 4 Negative ions generator The Negative ionis known as the vitamin in the air by medical...

Page 8: ... button slightly to set the timing digital screen show 0H to 12H 0H means no setting Under water shortage status long press TIMER AUTO for 3s can cancel WATER reminder lamp flashing 5 AUTO MODE button Touch the auto key indicator lights on wind speed will be adjusted automatically and touch the button again will exit the auto mode 6 FILTER button When the Filter replacement indicator flashes the u...

Page 9: ...er layer Pic 9 prepare them for the handle 3 Install the new filters 4 Close the front panel 5 Long press for 3s to renew the filter service program Pic 5 Pic 6 Pic 7 Pic 8 Pic 9 2 THE HUMIDIFIER FUNCTION To fill the tank with water 1 When water is shortage the water word is light up to remind injecting water Pic 10 2 Pull put water tank take out the wet cotton inject water Pic 11 3 Open cover cle...

Page 10: ...be easily cleaned please use the a soft cloth and dip a little bit neutral detergent to clean Note When maintenance please do not use hard material to scratch the machine cover Please operate under the instructions before take off the front cover and do not damage the machine parts WARNING Before the maintenance the power supply must be turned off Pic 13 ...

Page 11: ...ser manual PART 7 ELECTRICAL SCHEMATIC DIAGRAM Dust sensor WIFI module Reed switch Infrared remote control receiver Micro Switch board Negative I on generator Plastic encapsulated motor Control panel Power Supply Board Pic 14 ...

Page 12: ... flow it takes longer to purify the room air due to the entry of dirty outside air 3 The machine is placed in a small place or near obstacles affecting the purification effect 4 The filter dirty affecting the purification effect clean or replace the filter Here is smell from outlet 1 Because many people smoking barbecue etc in the room causing a lot of smell It is recommended to ventilate the room...

Page 13: ...NOTES ...

Page 14: ...NOTES ...

Page 15: ...NOTES ...

Page 16: ...www rotenso com email info rotenso com Installer stamp ...

Reviews: