Temperature Definition
This option allows assigning specific temperature sensors for various brood setups and for
heater zones. Moreover, assigning sensors to particular devices is possible. Note that if
the sensors selection remains empty the default value will be assigned to it .
Choose 1 to 9 temperature sensors for each item listed by using the '+/-' keys. The house,
brooding and tunnel sensors cause the current average to apply to devices, when no
specific sensor is assigned to them. The current average substitutes for either failed or
missing sensors.
Assign Temperature Sensors as required in
Install | Temp Definition
. Devices that do not
accept temperature sensors, such as Exhaust Fans, Tunnel Fans, Feed and Light do not
appear.
Note that Exhaust Fans and Tunnel Fans do not appear because the Ventilation Levels
defined in
Device | Levels of Ventilation
control their operation. On the other hand, Stir
Fans appear even though the
Device | Stir Fan Levels
apply to them, because they
simultaneously operate according
Device | Stir Fan Programs
where specific sensor
assignments are required in Program B and recommended in Program C.
8.8
Fan Air Capacity
This option enables the user to define the capacity of fans air. Insert fan air capacity for
both the exhaust and tunnel fans. The units are as chosen in
INSTALL | SETUP.
Press
+/-
Key-
to add/remove
to assign temp. sensors to
corresponding function.
Enter
+/-
Define air capacity for exhaust/tunnel
fans (Default setting shown above)
Enter
NOTE:
If an attic sensor is not installed, then the
attic vent will operate according to the average
.
This information will enable the display of air capacity for
each level in the Levels of Ventilation table (Precision ONLY)