Note:
You need at least one radiant heater
assigned to a relay to see these parameters.
Radiant Heaters HELP | SET Definitions:
•
U
Radiant Low – Differential from Heat Set:
U
Set degree of difference from Heat for LOW
Radiant Heaters to begin working. This
differential can be positive or negative. (Default: 2.0)
•
U
Radiant High – Differential (Below Low Set):
U
Set number of degrees below Radiant
Low Heaters for HIGH Radiant Heaters to begin working. (Default: 1.0). However, the
Radiant High heaters turn on for the Radiant Ignition Time with the Radiant Low
Heaters to ensure proper heater ignition.
•
U
Radiant Ignition Time (sec):
U
Set number of seconds to power radiant ignition.
(Default: 30).
Note:
The Heater Temp. Band applies to radiant heaters as well. For example, if the
Heat Temperature is 80ºF and the Heater Temperature Band is 1ºF, then heaters turn
on at 79ºF and off at 80ºF. If the Radiant Low Differential is at 2.0ºF, then radiant
heaters turn off at 82ºF, and on 1ºF below that at 81ºF. However, a Radiant High
Heater turns on regardless of its temperature setting for the Radiant Ignition Time
whenever the corresponding Radiant Low Heater turns on. This feature ensures proper
flame ignition.
Radiant Heater Differentials
ºF
81
ºF
82
ºF
80
Heat Temperature
Heaters
Off
Radiant High Off
Radiant Low Off
Low Radiant Diff
may be negative
Radiant Diff Hi