HELP | SET Definitions:
•
U
Wind Gust Delay Time (sec)
U
:
Set length of time in seconds before starting Static
Pressure control after an unexpected change in air pressure.
•
U
Static Pressure During Tunnel
U
:
Select YES or NO for using Static Pressure control
when in Tunnel mode.
•
U
Transitional Tunnel
U
:
Select YES or NO for using tunnel inlets when static pressure is
high and vents are already at 100%
•
U
MinVent Using vent/curtain
U
:
Select Vent=0 or Curtain=1 for controlling static pressure
when in minimum ventilation.
•
U
Incoming Air Low Temp. (Deg.)
U
:
Define low temperature for static pressure control.
•
U
Incoming Air High Temp. (Deg.)
U
:
Define high temperature for static pressure control.
•
U
Emergency Static Pressure Delay (sec)
U
:
Set length of time in seconds before
initiating emergency open when pressure exceeds high alarm setting.
•
U
Curtain Position in Emergency Static Pressure (%)
U
:
Set the desired curtain position
(in percentage) when an emergency pressure event occurs.
•
U
Low Static Pressure Alarm Min. Level (MinV)
U
:
Below this level the controller ignores
low static pressure alarms.
•
U
Low Static Pressure Alarm Min. Level (Tun.)
U
:
Below this level the controller ignores
low static pressure alarms while in tunnel mode.
•
U
Time to Produce Static Pressure (sec)
U
:
Enter the length of time to reach target
pressure when minimum ventilation fan cycle is on.
•
U
Attic Advance Opening Time (sec)
U
:
Define the amount of time for the attic inlet to
open before min vent cycling fans turn on.
Enter
Help