Gebrauchsanweisung ○
Mode d
’
emploi
○
Istruzioni per l
’
uso
○
Instructions for use
53
Installing the unit
o
Move the machine with installed exhaust pipe and
fittings towards the window. Distance between the
unit and adjacent walls or other objects shall be
least 50 cm (as shown in Fig. 4).
Notes:
o
The flat end of the exhaust pipe joints must be
snapped into place.
o
The pipe cannot be distorted nor has substantial
bend (greater than 45 °). Keep the ventilation of the
exhaust pipe unobstructed.
o
Elongate the exhaust pipe and snap the flat end of it into the elliptical hole of the win-
dow sealing plate.
Caution:
o
The length of the exhaust pipe shall be 280~1,500 mm, and this length is based on the
specifications of this air conditioner. Do not use extension tubes or replace it with a
different pipe, as this may cause a malfunction.
o
Exhaust must be unobstructed; otherwise it may cause overheating.
Figure 4