background image

9

Specifications

Continuous Power Output

60 watts/channel (20-20 kHz, < 0.03%, 8 ohms)

Total Harmonic Distortion (20Hz-20kHz)

< 0.03% at rated power, 1/2 power, or 1 watt

Intermodulation Distortion (60 Hz : 7 kHz, 4:1)

< 0.03% at rated power, 1/2 power or 1 watt

Frequency Response

Phono Input

20Hz-15kHz, 

±

0.2dB

Line Level Inputs

10Hz-100kHz, +1, –3dB

Damping Factor (20-20,000 Hz, 8 ohms)

150

Line Input Sensitivity / Impedance

160 mV / 24 kOhms

Line Input Overload

5 V

Phono (MM) Sensitivity / Impedance

2.4mV /47 kohms

Input (Phono) Overload

170 mV

Preamplifier Output / Impedance

1V / 470 ohms

Signal to Noise Ratio (IHF “A” weighted)

>95 dB

Power Requirements

USA:

115 Volts, 60 Hz

EC:

230 Volts, 50 Hz

Power Consumption

300 Watts

Dimensions (W x H x D)

430 x 92 x 355 mm
17 x 5

5

/

8

 x 14 inches

Front Panel Height

80mm / 3

3

/

16

 inches

Weight (net)

7.8 kg, 17.2 lbs.

All specifications are accurate at the time of printing.

Rotel reserves the right to make improvements without notice.

Rotel and the Rotel HiFi logo are registered trademarks of The Rotel Co, Ltd., Tokyo, Japan.

Troubleshooting

Most difficulties in audio systems are the re-
sult of incorrect connections, or improper
control settings. If you encounter problems,
isolate the area of the difficulty, check the
control settings, determine the cause of the fault
and make the necessary changes. If you are
unable to get sound from the RA-1062 refer
to the suggestions for the following conditions:

Power Indicator Is Not Lit

The power indicator should be lit whenever
the RA-1062 is plugged into the wall power
outlet and the POWER switch is pushed in. If
it does not light, test the power outlet with
another electrical device, such as a lamp. Be
sure the power outlet being used is not con-
trolled by a switch that has been turned off.

Fuse Replacement

If another electrical device works when plugged
into the power outlet, but the power indica-
tor still will not light when the RA-1062 is
plugged into the wall outlet, it indicates that
the internal power fuse may have blown. If
you believe this has happened, contact your
authorized Rotel dealer to get the fuse replaced.

No Sound

Check the signal source to see if it is functioning
properly. Make sure the cables from the sig-
nal source to the RA-1062 inputs are connected
properly. Be sure the LISTENING selector is
set to the proper input. Be sure the SPEAK-
ERS selector is set to the proper position. Check
the wiring between the RA-1062 and the
speakers.

English

Summary of Contents for RA-1062

Page 1: ...e Integrato Stereofonico Amplificador Integrado Estereofónico Geïntegreerde Stereo Versterker Integrerad Stereoförstärkare STEREO INTEGRATED AMPLIFIER RA 1062 PHONES RECORDING LISTENING CD AUX TUNER TAPE 1 TAPE 2 PHONO OFF CD TUNER TAPE 1 AUX PHONO CONTOUR L 1 L 2 LH SPEAKERS A OFF B A B POWER OFF H BALANCE ...

Page 2: ...ling Keep the component away from radiators heat registers stoves or any other appliance that produces heat The unit must be connected to a power supply only of the type and volt age specified on the rear panel of the unit Connect the component to the power outlet only with the supplied power supply cable or an exact equivalent Do not modify the supplied cable in any way Do not attempt to defeat g...

Page 3: ...E 2 PRE OUT AUX LEFT RIGHT LEFT RIGHT R L 12V TRIGGER OUT LEFT SPEAKER A RIGHT LEFT SPEAKER B RIGHT A AND B 8 OHMS MINIMUM A OR B 4 OHMS MINIMUM WARNING TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOTEXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE INTEGRATED AMPLIFIER MODEL NO RA 1062 POWER CONSUMPTION 300W SPEAKER IMPEDANCE RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION WARNING SHOCK HAZARD DO NOT OP...

Page 4: ...THIS EQUIPMENT TO RAIN OR MOISTURE INTEGRATED AMPLIFIER MODEL NO RA 1062 POWER CONSUMPTION 300W SPEAKER IMPEDANCE OPEN CAUTION Figure 3 Signal Input and Speaker Output Connections Signaux d entrée et branchements enceintes acoustiques Signaleingang und Anschluss eines Lautsprecherpaares Collegamenti dei segnali linea in ingresso e dei diffusori Conexiones para Entrada de Señal y Salida a las Cajas...

Page 5: ...n have been examined to ensure the most faithful music reproduction In addition the RA 1062 has independent input signal selectors for listening and recording They allow you to listen to one signal source while recording another The main functions of the RA 1062 are easy to install and use If you have experience with other stereo systems you shouldn t find any thing perplexing Simply plug in the a...

Page 6: ...erly The operation of the remote sensor can also be affected if it is exposed to bright sunlight or certain types of lighting such as halogen lights that emit infrared light In addition re mote control functions may not work reliably if the batteries in the RR AT92 are weak NOTE To use the remote aim it at the re mote sensor on the front panel of the RA 1062 Remote Control Batteries Two UM 4 AAA s...

Page 7: ...ly that will be a conventional tape recorder There are two sets of tape connec tions on the back panel labelled TAPE 1 and TAPE 2 When connecting a recorder to the RA 1062 the outputs of the recorder must be connected to the tape inputs of the RA 1062 Similarly the tape outputs of the RA 1062 must be connected to the inputs of the recorder Be sure to connect the left and right channels of each dev...

Page 8: ...ted for listening While recording you may still select a different source using the LIS TENING selector If you have a three head recorder or a DAT recorder that allows simultaneous read and write operation you can monitor your record ing by setting the LISTENING switch to the TAPE 1 or TAPE 2 position NOTE If you select TAPE 1 with the RE CORDING control the recording signal will only be available...

Page 9: ...ctions or improper control settings If you encounter problems isolate the area of the difficulty check the control settings determine the cause of the fault and make the necessary changes If you are unable to get sound from the RA 1062 refer to the suggestions for the following conditions Power Indicator Is Not Lit The power indicator should be lit whenever the RA 1062 is plugged into the wall pow...

Page 10: ... 01864 2699 USA Phone 1 978 664 3820 Fax 1 978 664 4109 Rotel Europe Dale Road Worthing West Sussex BN11 2BH England Phone 44 0 1903 221 600 Fax 44 0 1903 221 525 Rotel Deutschland Kleine Heide 12 D 33790 Halle Westf Germany Phone 49 05201 87170 Fax 49 05201 73370 www rotel com 082 OMRA 1062 042203 English Français Deutsch Italiano Español Nederlands Svenska ...

Reviews: