TROUBLESHOOTING
Display
Cause
Solution
„FULL“LED
is on permanently
Container is full
Empty container
Water pump failure or water
level sensor failure
Please contact
your local service
center if the
problem persists
Child lock + 9h
Temperature sensor error
Child lock + 6h
Humidity sensor error
Child lock + 3h (only MDS80-C05/B05) Heating problem
Warning: only authorised technicans can carry out repairs.
Problem
Solution
Display light not on
o
Check if the mains plug is inserted
o
Check if a programme is selected
o
Check the main power supply
“Full” LED on permanently
o
Empty water container
o
Check hose of the condensation outlet
Dryer does not start
o
Check if the start button is pushed
o
Check if the the door is closed
o
Check if a programme is selected
Water is running out
o
Align dryer horizontally
o
Clear air condenser and door seals
Door opens by itself
o
Press door
until it “clicks”
into position
o
Check if the amount of clothes reaches overload
Humidity in the room increases sig-
nificantly
o
Ventilate room adequately.
o
Clean the cool grille.
o
Ensure that the air condenser has been inserted
Degree of dryness was not reached
or drying time too long
o
Clean door and base filter
o
Empty water container
o
Check water outlet
o
Keep the air inlet clear
Warning: If you cannot deal with the fault by yourself and need help:
o
Press the
【
On/Off
】
button
o
Pull out the mains plug and call a service technician