![Rotax 125 JUNIOR MAX evo Installation Manual Download Page 25](http://html1.mh-extra.com/html/rotax/125-junior-max-evo/125-junior-max-evo_installation-manual_1489744025.webp)
BRP-Rotax
INSTALLATION INSTRUCTION
Figure 4.2
Step
Procedure
4
Connect pick-up connector to pick-up
sensor (pos. 1). Pay attention to the
engagement of the connector.
Figure 4.3
Step
Procedure
5
Fix the shift contact cable and the pos-
sibly too long cable (pos. 1) of the
pick-up sensor (pos. 3) with the pre-
mounted tie wrap (pos. 2) onto the
mounting plate.
Figure 4.4
NOTE
The shift contact cable must be isolated, be-
cause there is no use on non-gear engines.
For engines without exhaust slide only:
In the following figure you see the laying of the wiring
harness on engines without exhaust slide. Also you
see a dummy plug (part no. 666900) as an option,
which is not included in the scope of delivery. It can
be secured using tie wraps instead of the solenoid
valve.
Figure 4.5
Step
Procedure
6
Attach the ignition cable onto the wir-
ing harness.
Effectivity: 125 MAX evo, Junior MAX
evo, Mini MAX evo, Micro MAX evo