6.
Action
in the event of a fault
18
117592
●
03/2013
6.4 Recommissioning the lift
after incorrect alignment of the
slider blocks
If the slider blocks are not horizontally aligned
at the same level (outside the approved
control limits), halt operation of the lift and
check for the cause.
An alignment error such as this may be caused by:
An obstacle which is hampering the slider
blocks or the arm: Remove the object.
A mechanical safety latch is still engaged
Check the status and adjust the latch control cable
(Fig. 25)
The weight is very unevenly distributed: see the
chapter “Emergency lowering during a power
failure“
A synchronisation cable has become slack for
no obvious reason: press the "Up” button, to
tension the cable again (Fig. 25)
A synchronisation cable or a lifting chain is
damaged: set the main switch to “0“ and lock
with the key switch. Replace the damaged part.
If the malfunction cannot be repaired, please
contact the customer service at your authorised
dealer.
15
i
Short cable clamp
Latch
Cable clamp
Secondary column
Anchor
Long cable clamp
Mounting plate
Primary
column
Latch
Cable clamp