Intended use
The lift is intended to be used to lift and lower
commercial vehicles for repair, maintenance and
cleaning during normal workshop operation.
The lift is only to be used as intended, in techni-
cally sound condition according to technical
specifications.
The maximum load capacity of one lifting column
is 6200 kg and must not be exceeded. The permis-
sible load distribution in or against drive direction
is 2:1.
Standing or working under suspended load is per-
mitted.
Misuse
Improper behavior can cause danger to life and
health of persons working in the vicinity of the lift.
The manufacturer is not responsible for damages
caused by use against regulations and misuse.
Prohibited:
•
Standing and riding on load and load-bearing
equipment.
•
Standing or working under the load during lifting and
lowering.
•
Lifting of vehicles loaded with hazardous goods.
•
Lift installation in explosive areas.
The lift
Mode of operation
•
The lift is used to lift heavy vehicles for maintenance,
cleaning or repair to optimum working height.
•
Operation is carried out with a mobile control
panel.
•
Lifting and lowering the vehicle is carried out in jog
mode.
•
Electronic controls ensure level lifting of the vehicle.
•
The lift columns are movable in vehicle longi-
tudinal direction to adjust for different distances
between axles.
Specifications
Value
Lifting System
Inverted Rod Hydraulic
Cylinder
Electrical System
Battery
24V DC - 2 12V Deep
Cycle Batteries
Exide: NG27 or NG31
Capacity
6
,
200 Kg. Each Column
Fluid Capacity
11 Liters
Lifting Height (Cylinder
Stroke)
1753mm
Lifting Time At Capacity
72 Seconds
Lowering Time At
Capacity
54 Seconds
AMPS
140
Motor
3kW
Number of Cycles
(At Full Charge)
14 Cycles At Capacity
Suspension
Load bearing steel
wheels (Legs) And Glass
Filled Nylon (Steering)
Wheels With Sealed
Roller Bearings And
Adjustable Height
Fork Adjustment
Positions
5
Relief Pressure
180 Bar
Working Pressure
166 Bar
Shipped Weight
620 Kg.
Concrete Floor Slope
20 MPa Min. Strength
Min. 115mm Thick
10.5mm Per Meter Side
To Side
21.0mm Per Meter Fore
To Aft
Noise Level [db(A)]
80
Ambient Temperature
5.. 40°C