5.

Step 3. Placement of cover and defibrillator

Step 4. Electrical wiring

Attach the nylon strap to the cover using the small bolt 

and nut.

After mounting the cover you can place the defibrillator 

on the platform. Use the elastic band to secure the 

defibrillator.

You can now place the cover on the backplate. Align the 

recess on the top of the cover with the special marker on 

the top left of the back plate. Make sure the steel hook on 

the bottom is in the cover before you start rotating. Turn 

the cover to the right until it cannot move further to the 

right. The steel hook now falls through the opening at the 

bottom of the hood. Your Rotaid is mounted correctly.

Please now proceed with Step 4.

IMPORTANT! 

Always place the transformer unit inside since it is not 

suitable for outdoor usage. Never place the transformer 

unit inside the Rotaid cabinet!

Note:

Place the 

transformer 

inside at  

all times!

Cut the cable to the required length

and strip the outer cable (about 2 cm)

Remove 5 mm of the isolation of both cables.

Place the crimp sleeve insulator over the cable.

Connect both wires to the connector

Place the crimp sleeve over the connecter 

and use a heat gun to fixate. You can also isolate / 

fixate the connector with tape.

Connect the connector to the plug of the transformer 

(male – female)

Now connect the power plug to the transformer 

and plug the power cable into the wall outlet.

The LED lighting in the cabinet is now activated 

and will be on constantly. This indicates your 

installation has been succesfull.

Your Rotaid 24/7 is now ready for use!

1.

2.

3.

4.

5.

6.

7.

8.

9.

Cable brown

Cable blue

Step 5.  Activate your Rotaid 24/7 system

Please follow the instructions on the Rotaid 24/7 voucher 

to actívate your Rotaid 24/7 account.

EN

Summary of Contents for 24/7

Page 1: ...1 Installation Manual...

Page 2: ...illing template Polycarbonate backplate Polycarbonate cover Rotaid 24 7 module Transformer unit and power cord Fastening materials Drilling Template This Rotaid package contains Screw Set 4x Tapping s...

Page 3: ...47 com 31 0 478 769 052 Index English instructions Nederlandse instructies Instructions en Francais Deutsche Anleitung Instruzione Italiano Polskie instrukcje Danske instruktioner Norske instruksjoner...

Page 4: ...o assist you with this step On the bottom left of the backplate a rubber plug is located Use an awl or screwdriver to puncture this plug to allow for enough space for the power cable Run the whole pow...

Page 5: ...itable for outdoor usage Never place the transformer unit inside the Rotaid cabinet Note Place the transformer inside at all times Cut the cable to the required length and strip the outer cable about...

Page 6: ...t bevindt zich een rubberen plug Gebruik een priem of schroevendraaier om deze plug te doorboren zodat er voldoende ruimte is voor de stroomkabel Leid de hele stroomkabel door het gat en de muur BELAN...

Page 7: ...e buitenlucht Plaats bovendien de transformator nooit in de Rotaid kast Let op Plaats de transformator altijd binnen Knip de kabel op de gewenste lengte en verwijder circa 2 centimeter van de kabeliso...

Page 8: ...he de la paroi arri re se trouve un bouchon en caoutchouc Utilisez un poin on ou un tournevis pour percer ce bouchon afin de laisser suffisamment d espace pour le c ble d alimentation Faites passer to...

Page 9: ...convient pas une utilisation en ext rieur Ne placez jamais le transformateur l int rieur de l armoire Rotaid Coupez le c ble la longueur requise et d nudez le c ble ext rieur environ 2 cm Retirez 5 mm...

Page 10: ...atte befindet sich ein Gummistopfen Verwenden Sie eine Ahle oder einen Schraubendreher um diesen Stopf zu durchstechen damit gen gend Platz f r das Netzkabel vorhanden ist F hren Sie das gesamte Strom...

Page 11: ...nicht f r den Au enbereich geeignet ist Stellen Sie die Transformatoreinheit niemals in den Rotaid Schrank Schneiden Sie das Kabel auf die gew nschte L nge ab und entfernen Sie das u ere Kabel ca 2 c...

Page 12: ...teriore si trova un tappo di gomma Utilizzare un punteruolo o un cacciavite per perforare questa spina per consentire spazio sufficiente per il cavo di alimentazione Far passare l intero cavo di alime...

Page 13: ...ormatore all interno poich non adatta per l uso esterno Non posizionare mai il trasformatore all interno dell armadio Rotaid Tagliare il cavo alla lunghezza richiesta e spellare il cavo esterno circa...

Page 14: ...lnym rogu tylnej p yty znajduje si gumowa za lepka Przebij za lepka pomoc szyd a lub rubokr ta aby zapewni wystarczaj c ilo miejsca na kabel zasilaj cy Przeprowad ca y kabel zasilaj cy przez otw r i c...

Page 15: ...mator w rodku poniewa nie nadaje si do u ytku na zewn trz Nigdy nie umieszczaj transformatora w szafce Rotaid Przytnij kabel do wymaganej d ugo ci i zdejmij kabel zewn trzny oko o 2 cm Usu 5 mm izolac...

Page 16: ...nden person til at hj lpe dig med dette trin Nederst til venstre p bagpladen findes et gummiprop Brug en vinkel eller skruetr kker til at punktere dette prop for at give plads nok til str mkablet K r...

Page 17: ...ke er egnet til udend rs brug Placer aldrig transformatorenheden i Rotaid kabinettet Klip kablet til den nskede l ngde og strip det ydre kabel ca 2 cm Fjern 5 mm af isoleringen af begge kabler Placer...

Page 18: ...elp fra en annen person til hjelpe deg med dette trinnet Nederst til venstre p bakplaten er en gummiplugg plassert Bruk en stang eller skrutrekker for punktere denne pluggen for gi nok plass til str m...

Page 19: ...siden den ikke er egnet for utend rs bruk Plasser aldri transformatorenheten i Rotaid skapet Notat Plasser transformatoren inne til enhver tid Klipp kabelen til nsket lengde og strip den ytre kabelen...

Page 20: ...a i h len 150 CM Detta steg kr ver tv personer L ngst ner till v nster p bakplattan finns en gummiplugg Anv nd en syl eller en skruvmejsel f r att g ra ett h l i pluggen f r str mkabeln F r hela str m...

Page 21: ...f r utomhusbruk Placera aldrig transformatorn i Rotaidsk pet Notera Placera transformatorn inuti hela tiden Kapa kabeln till nskad l ngd och skala av det yttre h ljet ca 2 cm Ta bort 5 mm av isolerin...

Page 22: ...En la parte inferior izquierda de la placa posterior se encuentra un tap n de goma Use un punz n o un destornillador para perforar este enchufe y dejar suficiente espacio para el cable de alimentaci n...

Page 23: ...l interior ya que no es adecuada para uso en exteriores Nunca coloque la unidad transformadora dentro del gabinete rotativo Nota Coloque el transformador adentro en todo momento Corte el cable a la lo...

Page 24: ...24 Keizersveld 52D 5803 AN Venray The Netherlands rotaid247 com support rotaid247 com 31 0 478 769 052...

Reviews: