Page 40
07/04
Replacing a lost Programming Code
1)
Remove power from the AC-F43
2)
Press the REX button
3)
Apply power to the unit with REX button pressed
4)
Release the REX button
5)
You now have 15 seconds to program a new Programming Code
into the unit using the initial default code 1234, before the
controller reverts to the existing code.
Replacing a lost Normal / Secure Code
1)
Remove power from the AC-F43
2)
Press the REX Button
3)
Apply power to the unit with REX button pressed.
4)
Release the REX Button
5)
You now have 15 seconds to program a new Normal / Secure
code 3838 in order to return to Normal Mode, where you may
enter programming mode to program a new Normal / Secure
code.
Note:
The AC-F43 must be in Normal Mode otherwise this will
not work. Make sure that the Mode LED is green before
proceeding.
Note:
The AC-F43 must be in Secure Mode otherwise this will
not work. Make sure that the Mode LED is red before
proceeding.
AC-F43
Glossary
valid users. In this mode the door
A
may be released by anyone pressing
Access Control:
Primarily refers to
the star button.
a device or set of devices controlling
C
the entry of people traveling through
a door or set of doors.
Cards:
See Proximity Cards
Ajar Delay:
The time allowed for a
Case Tamper:
The electronic
door to be left open before sounding
tamper signal advising the controller
an alert and / or activating the
that
the
case
has
been
opened.
Auxiliary Relay.
Code Assignment:
The process of
Amplitude Shift Keying (ASK):
The
assigning which Output(s) (Lock
typ e of dat a com mun ica tio ns
Strike Relay and / or Auxiliary Relay)
between the Proximity Card and the
are to be activated when a valid code
Proximity Reader.
is entered.
ASK:
An abbreviation of "Amplitude
D
Shift Keying".
Direct Shunt:
The arrangement in
Auxiliary Input:
The term used for
which an external input (such as a
the programmable input electrical
door monitor) is connected directly to
signal from an external device such
the Auxiliary Relay allowing the
a Door Monitor switch or Auxiliary
Auxiliary Output to be activated after
REX button.
the direct shunt delay elapses. This
Auxiliary Code:
The four digit code
leaves the Auxiliary Input available
used to activate the Auxiliary Output
for Normal / Secure mode toggle.
f o r t e s t i n g p u r p o s e s d u r i n g
Default Factory Setting:
The
installation.
settings that the controller is
Auxiliary Output:
The term used for
preprogrammed with when the
the Relay Output in the AC-F43 that
controller is manufactured.
may be programmed to activate upon
Direct Shunt Delay:
The delay time
different system events such as
(user programmed) used in Direct
Tamper, Forced Door Event, Door
Shunt (See Direct Shunt).
Ajar, etc.
Door Bell:
The alert sound activated
B
when the door star button on the AC-
Back Tamper:
The ele ctr oni c
F43 is pressed. (Requires the BL-
tamper signal advising the controller
D40 External Sounder)
that the controller has been removed
Door Chime:
The alert sound
from
the
wall.
activated when the lock strike
Bypass Code:
The four digit code
unlocks the door after a valid code
used to ch ange the M ode o f
has been presented. (Requires the
Operation of the AC-F43 from
BL-D40
External
Sounder)
Normal to Bypass Mode or vice
versa.
Bypass Mode:
A Mode of Operation
where door access is not restricted to
Page 41
07/04
AC-F43