Changing the Open Code

Changing the Auxiliary Code

The Open Code is mainly used as a method to quickly test the 
Lock Strike Relay during installation.

The Default Factory Setting for the Open Code is 2580.
When the first user is added to the controller, the default Open 
Code will automatically be deleted, ready for a new Open Code  
to be re-entered.

1)

 Enter Programming Mode

2)

 Press

 "1" 

to enter 

Menu 1

!

 The Mode LED will turn red

3)

 Enter the new 4-digit code you

wish to set as Open Code.

4)

System returns to Normal Mode

!

 You will hear three beeps

!

 The Door LED will turn off

!

 The Mode LED will turn green

Note:

- Open Code does not function in Secure Mode.
- Wrong entries: you will hear a long beep and the  

                  controller will return to Normal Mode.

- Code 0000 will erase and deactivate the Open Code.

The Auxiliary Code is mainly used as a method to quickly test the 
Auxiliary Relay during installation.The Default Factory Setting for  

    the Auxiliary Code is 0852.

    For security reasons when the first user is added to the controller   
    or the open code is changed, the default Auxiliary Code will  
    automatically be deleted, ready for a Auxiliary Code to be 
    assigned.

Page 22

07/04

AC-F43

Mode

Door

GREEN

Mode

Door

GREEN

RED

?

?

?

?

Mode

Door

GREEN

Page 23

07/04

1)

 Enter Programming Mode

2)

 Press 

"2"

 to enter 

Menu 2

!

 The Mode LED will turn red

3)

 Enter the new 4-digit code you

wish to set as Auxiliary Code.

4)

System returns to Normal Mode

!

 You will hear three beeps

!

 The Door LED will turn off

!

 The Mode LED will turn green

Note:

- Auxiliary Code does not work in Secure Mode.
- Auxiliary Code only works when the Auxiliary Mode is 0, 

1, 8 or 9.

- Code 0000 will erase and deactivate  the Auxiliary 

Code.

1)

 Enter Programming Mode

2)

 Press

 "3"

 to enter 

Menu 3

!

 The Mode LED will turn green.

3)

 Enter the new 4-digit code you

wish to set as Programming Code

4)

System returns to Normal Mode

!

 You will hear three beeps

!

 The Door LED will turn off

!

 The Mode LED will turn green

Note:

- Programming Code can not be erased, i.e. the code

0000 is not valid and will not erase the Programming 
Code.

Changing the Programming Code

AC-F43

Mode

Door

Mode

Door

GREEN

GREEN

Mode

Door

GREEN

GREEN

?

?

?

?

Mode

Door

GREEN

Mode

Door

GREEN

Mode

Door

GREEN

?

?

?

?

ORANGE

Summary of Contents for AC-F43

Page 1: ...INSTRUCTION MANUAL AC F43 WATERPROOF STAND ALONE ACCESS CONTROL UNIT WITH BACKLIT KEYPAD 07 04 ...

Page 2: ...xternal Sounder 19 PROGRAMMING THE AC F43 20 Entering Programming Mode 21 Exiting Programming Mode 21 1 Changing the Open Code 22 2 Changing the Auxiliary Code 22 3 Changing the Programming Code 23 4 Changing the Normal Secure Code 24 5 Changing the Normal Bypass Code 24 Door Chime Settings 24 6 Setting Fail Safe Secure Operation 26 Setting Tamper Siren Time 26 Setting the Lock Strike Release Time...

Page 3: ...ressed 4 BL D40 External Sounder Optional Provides Siren Bell and Chime functions to AC F43 Other Rosslare accessories can be found at Rosslare s Web Site http www rosslaresecurity com AC F43 07 04 Technical Specification Electrical Characteristics Operating Voltage Range 12 to 24V DC From a Regulated Power Supply or 16 to 24V AC From a Transformer Maximum Input Current Standby 75mA Not including ...

Page 4: ... Programming Interface LED s Three User Levels Normal User Secure User Master User Three Modes of Operation Normal Mode Bypass Mode Secure Mode Code Search feature that helps make maintaining user codes easier Input for Request to Exit REX button Comes with mounting template for easier installation Built in Case and Back Tamper Bell Chime Siren and Strobe features available with BL D40 Programmabl...

Page 5: ...ng the security screw Page 9 07 04 Wiring the AC F43 The controller is supplied with a 22 60cm pigtail having a 10 conductor cable To wire the Controller perform the following steps 1 Prepare the controller cable to the required length 2 Splice the controller pigtail wires to the corresponding devices and cover each connection Refer to the wire color guide provided below and to the wiring diagrams...

Page 6: ...43 Transorb 1 5KE47C Connect to load terminals Optional transorb Not Supplied 07 04 Page 11 AC F43 Wiring the Auxiliary Input and Output IN MONITOR V IN COMMON POWER SUPPLY 12V 24V DC or 16V 24V AC FROM TRANSFORMER Auxiliary Load AUXILIARY INPUT MONITOR AUX IN IN MONITOR COM N C N O AUX GROUND BLACK RED WHITE YELLOW ORANGE BLUE AC F43 Transorb 1 5KE47C Connect to load terminals Optional transorb f...

Page 7: ... Wiring the BL D40 External Sounder AC F43 REX BL REX BL BL D40 COMMON POWER SUPPLY 12V 24V DC or 16V 24V AC FROM TRANSFORMER V IN GROUND BLACK RED GREEN AC F43 Page 13 07 04 AC F43 THIS PAGE IS INTENTIONALLY BLANK ...

Page 8: ... any Mode of Operation by presenting their PIN code to the controller AC F43 07 04 Page 15 AC F43 Modes of Operation The AC F43 has 3 Modes of Operation 1 Normal Mode Mode LED is green Normal Mode is the default mode In Normal Mode the door is locked until a Primary Code is presented to the controller The controller can only be programmed in Normal Mode 2 Bypass Mode Mode LED is orange In Bypass M...

Page 9: ...r RED Mode Door Mode Door Mode Door RED GREEN GREEN 07 04 Changing from Normal Mode to Bypass Mode By default there is no Normal Bypass Code The Normal Bypass Code must first be programmed to use this function Refer to page 24 to create modify the Normal Bypass Code 1 Enter the 4 digit Normal Bypass Code Mode LED will flash orange 2 Press the key to confirm the Mode change Mode LED will turn orang...

Page 10: ...r receives a Tamper Event Signal it will activate a Siren and a Strobe Light The Siren time can be easily programmed in the AC F43 from 0 to 9 minutes The tamper event can activate the Auxiliary Output if the controller is in Auxiliary Mode 3 Refer to Setting the Auxiliary Mode on Page 27 Clearing a tamper event is done by entering a valid User Code AC F43 07 04 BL D40 External Sounder The BL D40 ...

Page 11: ... menu items on the following pages Page 20 07 04 AC F43 Menu Description Factory Settings Menu Number Page 21 07 04 Entering Programming Mode Exiting Programming Mode 1 Press the key two times within 2 seconds Mode LED will turn off Door LED will turn red 2 Enter your 4 digit Programming Code If the Programming Code is valid the door LED will turn green and the AC F43 will be in Programming Mode N...

Page 12: ...r is added to the controller or the open code is changed the default Auxiliary Code will automatically be deleted ready for a Auxiliary Code to be assigned Page 22 07 04 AC F43 Mode Door GREEN Mode Door GREEN RED Mode Door GREEN Page 23 07 04 1 Enter Programming Mode 2 Press 2 to enter Menu 2 The Mode LED will turn red 3 Enter the new 4 digit code you wish to set as Auxiliary Code 4 System returns...

Page 13: ...ys that the Normal Bypass Code and Door Chime can be programmed a Disable Bypass Mode Disable Door Chime b Disable Bypass Mode Enable Door Chime c Enable Bypass Mode Disable Door Chime d Enable Bypass Mode Enable Door Chime Page 24 07 04 AC F43 Mode Door GREEN Mode Door GREEN RED Mode Door GREEN Mode Door GREEN Mode Door GREEN ORANGE Page 25 07 04 a Disable Bypass Code Disable Door Chime Enter the...

Page 14: ...xplanation on each auxiliary mode refer to the Auxiliary Mode Reference guide on Page 29 AC F43 Mode Door GREEN Mode Door GREEN GREEN 2 Mode Door GREEN Setting Fail Safe Secure Operation Setting Tamper Siren Time Setting the Lock Strike Release Time The default factory setting is 0004 The Tamper Siren feature requires the BL D40 External Sounder 1 Enter Programming Mode 2 Press 6 to enter Menu 6 T...

Page 15: ...lay should be activated The auxiliary input can switch the mode of operation of the controller between Normal and Secure Mode By connecting a switch timer to the auxiliary input you can for example automatically switch the AC F43 from Normal Mode during office hours to Secure mode after office hours AUXILIARY MODE 3 In auxiliary mode 3 the auxiliary output is activated if the AC F43 is tampered i ...

Page 16: ...xiliary setting defines the forced door delay AC F43 Page 31 07 04 AUXILIARY MODE 7 In auxiliary mode 7 the AC F43 can trigger the auxiliary relay if it detects that the door has been ajar too long In this mode the auxiliary input should be wired to the magnetic contact switch on the door The auxiliary relay should be wired to the alarm system If the door is opened the controller will wait for the...

Page 17: ...t Code is unknown The Code Search method only works if a users Primary Code is already enrolled but the Secondary Code is not See Enrolling Users with the Code Search Method on Page 34 AC F43 Enrolling Primary and Secondary Codes using the Standard Method 1 Enter Programming Mode 2 Press 7 to enter Menu 7 The Door LED will turn orange 3 Enter the 3 digit User Slot number between 001 to 500 that yo...

Page 18: ...e entered AC F43 Mode Door GREEN Mode Door ORANGE 0 0 0 Mode Door ORANGE Mode Door RED ORANGE Deleting Primary Secondary Codes There are two methods to delete Primary and Secondary codes the Standard Method and the Code Search Method When deleting a User Slot both the Primary Code and the Secondary code are erased Deleting Primary and Secondary Codes using the Standard Method 1 Enter Programming M...

Page 19: ...enrolled for any user that user is assigned rights to activate the Lock Strike Relay when they present a valid code to the controller The Code Assignment Menu allows you to assign whether the Lock Strike Relay and or the Auxiliary Relay is activated when a user enters a valid code There are two methods to Assign Codes Standard Method and the Code Search Method Lock Strike Relay and Auxiliary Relay...

Page 20: ...n to Normal Mode If the assignment digit is invalid you will hear a long beep and the controller will wait for another assignment digit to be entered AC F43 Mode Door ORANGE GREEN Mode Door GREEN Mode Door ORANGE GREEN 0 0 0 Mode Door ORANGE GREEN Return To Factory Default Settings Warning You must be very careful before using this command Doing so will erase the entire memory which includes all U...

Page 21: ...io ns Strike Relay and or Auxiliary Relay between the Proximity Card and the are to be activated when a valid code Proximity Reader is entered ASK An abbreviation of Amplitude D Shift Keying Direct Shunt The arrangement in Auxiliary Input The term used for which an external input such as a the programmable input electrical door monitor is connected directly to signal from an external device such t...

Page 22: ...sa connected door locked Normal User A user who only has a Forced Door A door which has Primary Code and can only gain been physically opened without the access in Normal Mode access control device having Normally Closed A relay output released the lock from the controller that is activated Forced Door Time The amount of closed circuit under normal time user programmed the conditions controller wa...

Page 23: ...proper operation normal wear accident improper maintenance or modification This warranty does not cover repair or replacement where normal use has exhausted the life of a part or instrument Service life of the product is dependent upon the care it receives and the conditions under which it has to operate In no event shall Rosslare be liable for incidental or consequential damages Page 45 07 04 AC ...

Page 24: ...on Bay Hong Kong http www rosslaresecurity com Tel 852 2795 5630 Fax 852 2795 1508 E mail info rosslare com hk United States and Canada Rosslare NAPDC Suite 238 200 East Howard Street Des Plaines IL 60018 USA http www rosslaresecurity com Tel 866 262 8633 T oll Free Tel 847 827 6330 Direct Fax 847 827 6433 E mail support rosslare net ...