Input and Output Requirements
Double door controller:
(each door has two readers)
OUT1 = door1
OUT5 = door2
Four door controller:
OUT1 = door1
OUT2 = door2
OUT5 = door3
OUT7 = door4
The output can sink current from any power supply (see page 16).
An AC-525 output can provide 12 VDC power up to 1A for external door
locks. For higher rated door locks an external UL 294 Listed power supply
must be used to provide power to the door lock.
This restriction does not affect standard AC-525 models.
Note:
For UL installations, the installer must configure the system as
fail-safe to comply with NFPA (National Fire Protection
Association) regulations.
4.4
Card Readers and Keypads
Each access control panel can be connected to a maximum of two
readers or 4 readers when using MD-D02. There are three available types
of reader:
•
Card readers
•
Keypads
•
Dual keypad card readers
A keypad is required for any reader mode that requires PIN code entries,
such as "Card or PIN", "PIN Only" or "Card and PIN (Secured mode)".
When connecting a reader, the following should be defined:
Single door controller:
Door 1 – Reader 1 IN/OUT
Door 1 – Reader 2 IN/OUT
Double door controller:
Door 1 – Reader 1 IN/OUT
Door 2 – Reader 2 IN/OUT
When using the
MD-D02, the following should be defined:
Double door controller:
(each door has two readers)
Reader1 - door1 IN/OUT
Reader2 - door1 IN/OUT
Reader3 - door2 IN/OUT
Reader4 - door2 IN/OUT
Four door controller:
(each door has two readers)
Reader1 - door1 IN/OUT
Reader2 - door2 IN/OUT
Reader3 - door3 IN/OUT
Reader4 - door4 IN/OUT
Use the AxTrax AS-525 software to set the readers for IN or OUT use and to
set the data transmission format for each reader.