AC-215x Hardware Settings
AC-215x-B Series Hardware Installation Manual
29
Double Door
Outputs
Door1 Lock output
(OUT 1)
General purpose output
(OUT 1A)
Door2 Lock output
(OUT 2)
General purpose output
(OUT 2A)
Inputs
Door1 Request to exit
(IN 1)
Door1 monitor input
(IN 1A)
Door2 Request to exit
(IN 2)
Door2 monitor input
(IN 2A)
Readers
Reader1
(Door1 IN/OUT)
Reader2
(Door2 IN/OUT)
5.4
26B
Access Control Panel Addressing
The last five DIP switches are used to set the binary code of the access control
panel internal network address. The default access control panel address is
“1”.
For successful communications, the DIP switch must match the address set in
the AxTraxNG software.
Table 6 displays the 32 address settings available:
Table 6: Available Panel Addresses
Address Switch 4 Switch 5 Switch 6 Switch 7 Switch 8
1
OFF
OFF
OFF
OFF
OFF
2
OFF
OFF
OFF
OFF
ON
3
OFF
OFF
OFF
ON
OFF
4
OFF
OFF
OFF
ON
ON
5
OFF
OFF
ON
OFF
OFF
6
OFF
OFF
ON
OFF
ON
7
OFF
OFF
ON
ON
OFF
8
OFF
OFF
ON
ON
ON
9
OFF
ON
OFF
OFF
OFF
10
OFF
ON
OFF
OFF
ON
11
OFF
ON
OFF
ON
OFF
12
OFF
ON
OFF
ON
ON
13
OFF
ON
ON
OFF
OFF
14
OFF
ON
ON
OFF
ON
15
OFF
ON
ON
ON
OFF
16
OFF
ON
ON
ON
ON
17
ON
OFF
OFF
OFF
OFF