AC-215x Hardware Settings
28
AC-215x-B Series Hardware Installation Manual
Table 4 lists Switch 1 and 2 status and baud rate:
Table 4: Switch Baud Rates
Switch 1 Switch 2 Baud Rate
OFF
OFF
9600
OFF
ON
19200
ON
OFF
115200
ON
ON
57600
The access control panel baud rate must be identical to the AxTrax Network
configuration of baud rate.
5.3
Access Control Panel Type
The access control panel type is defined using the third DIP switch. There are
two panel types – a panel with one reader per each door or a panel with two
readers per each door. This DIP switch setting influences the number of doors
in the panel.
The default access control panel setting is for two readers per each door.
OFF
–
Defines using two readers for each door. Panel controls one door.
ON
–
Defines using one reader for each door. Panel controls two doors.
Select the appropriate DIP switch setting to operate the panel as either a single
door, a double door, or four doors (see Section
Access control panels configured as either single door or double door
controllers have two readers, IN or OUT.
Table 5 summarizes the possible hardware settings.
Table 5: Possible Hardware Settings
Single Door
Outputs
Door Lock output
(OUT 1)
General purpose output
(OUT 1A)
General purpose output
(OUT 2)
General purpose output
(OUT 2A)
Inputs
Request to exit
(IN 1)
Door monitor input
(IN 1A)
General purpose input
(IN 2)
General purpose input
(IN 2A)
Readers
Reader1
Door Entry or Exit
Reader2
Door Exit or Entry