![Rosslare AC-215 B Series Installation Manual And User'S Manual Download Page 11](http://html.mh-extra.com/html/rosslare/ac-215-b-series/ac-215-b-series_installation-manual-and-users-manual_1489227011.webp)
Technical Specifications
AC-215x-B Series Hardware Installation Manual
11
2.
Technical Specifications
2.1
AC-215x-DIN
Electrical Characteristics
Operating Voltage
12 VDC, 1.5 A from a regulated power supply
Maximum Input Current
AC-215
Standby: 80 mA
Maximum: 325 mA
AC-215IP
Standby: 120 mA
Maximum: 370 mA
General Inputs
•
4 supervised high impedance inputs
•
Maximum voltage: 5 VDC
Relay Outputs
4 Form C 5 Amp relay outputs
Reader Ports
•
2 reader ports
•
Communication: Wiegand (D0, D1) or Clock &
Data (C, D)
•
Output voltage to reader: 12 VDC
•
Max. current to reader: 245 mA
•
LED control output and Tamper Input
Visual Indicators
11 LEDs for outputs and communication status
Audio
Sounder output for use with compatible speakers
provide chime, bell and siren signals
Battery Standby Time
3 hours with a 12 V, 7 Ah lead acid battery
Communication Characteristics
RS-485 / RS-232
•
RS-485 or optional RS-232
•
RS-485 connection by terminal block or MD-14U
connector
•
RS-232 connection by terminal block
RS-232
Terminal Block
RS-485
Molex and Terminal Block
TCP/IP
On-board RJ-45 connector
(functional on AC-215IP models only)
Selectable Communication
Speed
9600, 19200, 57600, 115200 bps
Environmental Characteristics
Operating Temperature Range
0°C to 49°C (32°F to 120°F)
Operating Humidity Range
0 to 85% (non-condensing)
Dimensions
Height x Width x Depth
193 x 136.5 x 39 mm (7.6 x 5.4 x 1.5 in.)