Ross PS-8102 User Manual Download Page 4

6.

The product chassis is to be rack mounted only. To ensure safe operation and maintain 
long-term system reliability, proper installation requires that the front and back area of 
the chassis remain clear of obstructions so as not to restrict airflow.

EMC Notices

United States of America
FCC Part 15

This equipment has been tested and found to comply with the limits for a class A Digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference when the equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used 
in accordance with the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to cause harmful 
interference in which case the user will be required to correct the interference at his own expense.

CANADA

This Class “A” digital apparatus complies with Canadian ICES-003. 

Cet appariel numerique de la classe “A” est conforme a la norme NMB-003 du Canada.

EUROPE

This equipment is in compliance with the essential requirements and other relevant provisions of 

CE

 

Directive 93/68/EEC

.

INTERNATIONAL

This equipment has been tested to 

CISPR 22:1997

 along with amendments 

A1:2000

 and 

A2:2002

, and found to comply with the limits for a Class A Digital device.

Maintenance/User Serviceable Parts 

Routine maintenance to this RossGear product is not required. This product contains no user 
serviceable parts. If the module does not appear to be working properly, please contact Technical 
Support using the numbers listed under the “Contact Us” section on the last page of this manual. 
All RossGear products are covered by a generous 5-year warranty and will be repaired without 
charge for materials or labor within this period. See the “Warranty and Repair Policy” section in 
this manual for details. 

Indoor Use: Warning

 — To reduce the risk of fire or electric shock, do not 

expose this apparatus to rain or moisture.

Notice

 — Changes or modifications to this equipment not expressly approved by 

Ross Video Limited could void the user’s authority to operate this equipment.

Notice

 — This is a Class A product. In domestic environments, this product may 

cause radio interference, in which case the user may have to take adequate 
measures.

Summary of Contents for PS-8102

Page 1: ...Ross Video Limited DFR 8110A C Digital Products Frame and Power Supply PS 8102 User Manual...

Page 2: ...446 7 834 886 7 914 332 This product is protected by the following Canadian Patents 2039277 1237518 1127289 Other patents pending Notice The material in this manual is furnished for informational use...

Page 3: ...s intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product Failure to heed this information may present a ris...

Page 4: ...a norme NMB 003 du Canada EUROPE This equipment is in compliance with the essential requirements and other relevant provisions of CE Directive 93 68 EEC INTERNATIONAL This equipment has been tested to...

Page 5: ...ral resources Ross Video encourages you to use the appropriate take back systems These systems will reuse or recycle most of the materials from your end of life equipment in an environmentally friendl...

Page 6: ...O Box 880 Ogdensburg New York USA 13669 0880 General Business Office 1 613 652 4886 Fax 1 613 652 4425 Technical Support 1 613 652 4886 After Hours Emergency 1 613 349 0006 E mail Technical Support t...

Page 7: ...g Performance 2 4 Ventilation and Cooling 2 4 Cabling for the DFR 8110A C 2 6 Cabling Overview 2 6 Optional Field Upgrade Kits 3 CFM 8110A Cooling Fan Overview 3 2 Installing the CFM 8110A 3 2 CRB 811...

Page 8: ...ii Contents DFR 8110A C User Manual Iss 03...

Page 9: ...f products backed by Ross Video s experience in engineering and design expertise since 1974 You will be pleased at how easily your new DFR 8110A C fits into your overall working environment Equally pl...

Page 10: ...glitch while maintaining a full power output This is of great importance in areas where incoming power may not be clean Features The following features make the DFR 8110A C one of the finest digital...

Page 11: ...o the frame with the CFM 8110A Cooling Fan Module DFR 8110A C refers to all versions of the frame unless otherwise noted Operator and User refer to the person who uses DFR 8110A C Board and Card refer...

Page 12: ...1 4 Introduction DFR 8110A C User Manual Iss 03...

Page 13: ...allation 2 1 Installation In This Chapter This chapter provides instructions for installing the DFR 8110A C and cabling details The following topics are discussed Before You Begin Installing the DFR 8...

Page 14: ...ved from the shipping container and ensure that all items are included If any items are missing or damaged contact your sales representative or Ross Video directly ESD Susceptibility Static discharge...

Page 15: ...supply off before inserting or removing it from the frame will increase the life span of connectors Of great importance to the user who may have unstable or unpredictable facility power is the ability...

Page 16: ...nstalled should not exceed 40 Watts and to leave an empty 1RU panel space above and below the frame for improved heat dissipation For information on the power requirements of RossGear modules please r...

Page 17: ...performance it is recommended that the frame door not be opened for longer than 5 minutes when using the Cooling Fan Module option on frames loaded with more than 40 Watts Figure 2 1 Frame Stacking CF...

Page 18: ...the frame connect to an opto isolator circuit in the frame For example in the case of the SRA 8001A Serial Auto Reclocking Amplifier if the input signal is lost or low the INPUT STATUS Red LED will b...

Page 19: ...l that is distributed across the back plane to all modules Typically analog black video is used Some cards which need an external reference can use this master reference signal in place of taking the...

Page 20: ...2 8 Installation DFR 8110A C User Manual Iss 03...

Page 21: ...al Iss 03 Optional Field Upgrade Kits 3 1 Optional Field Upgrade Kits In This Chapter This chapter contains the following sections CFM 8110A Cooling Fan Overview CRB 8110A Card Retaining Bracket Suppo...

Page 22: ...oard to the side of the frame by inserting the two Screws 850 075 provided from the left side of the frame exterior In mobile applications secure screws with Loctite 3 Remove the protective film from...

Page 23: ...re to install the CRB 8100A 1 Install two plastic spacers on the threaded studs near bottom of the door Figure 3 2 Figure 3 2 CRB 8110A Installation 2 Mount the spacers to the door lower studs through...

Page 24: ...procedure to install the FSB 7110 for the DFR 8110A C 1 Choose the position that suits the cabinet depth and will give approximately inch projection beyond the rear vertical mounting rails 2 Using fou...

Page 25: ...User Manual Iss 03 Specifications 4 1 Specifications In This Chapter This chapter provides the technical specification information for the DFR 8110A C The following topics are discussed Technical Spe...

Page 26: ...requiring greater heat dissipation Table 4 1 DFR 8110A C Technical Specifications Category Parameter Specification Power Supply Input Voltage 100 240VAC 50 60Hz Input Power 2RU DFR 8110A 130W Output V...

Page 27: ...DFR 8110A C User Manual Iss 03 Service Information 5 1 Service Information In This Chapter This chapter contains the following sections Troubleshooting Checklist Warranty and Repair Policy...

Page 28: ...me and any associated peripheral equipment for signs of trouble 2 Power Check Check the power indicator LED on the distribution frame front panel for the presence of power If the power LED is not illu...

Page 29: ...ear DFR 8110A C User Manual provides all pertinent information for the safe installation and operation of your RossGear Product Ross Video policy dictates that all repairs to the RossGear DFR 8110A C...

Page 30: ...Notes...

Page 31: ...Notes...

Page 32: ...on Related products and full product lines On line catalog News Testimonials Ross Part Number 8110ADR 004 03 PHONE General Business Office and Technical Support 613 652 4886 After Hours Emergency 613...