DRA-8902 Series User Manual (Iss. 02)
DashBoard Menus • 4–7
Alarms Tab
summarizes the
Alarms
options available in DashBoard.
Table 4.5 Alarms Menu Items
Menu Title
Item
Parameters
Description
Input #
Invalid Signal
Selected*
The Status field in the Signal tab reports
the loss of the input as an error/alarm
Cleared
The Status field in the Signal tab reports
the loss of the input as information only
(status indicator does not report an alarm
condition)
Outputs -
Channel #
Channel # (read-only)
Outputs 1-2
Indicates the OUT BNCs included in the
channel
Outputs 3-4
Outputs 5-10
Outputs 10-16
Invalid Signal
Selected*
The specified Channel field in the Output
Status area of the Signal tab reports the
detected invalid input as an error/alarm
Cleared
The specified Channel field in the Output
Status area of the Signal tab reports that an
invalid input is detected, but as
information only (status indicator does not
report an alarm condition)
Failover
Selected*
The specified Channel field in the Output
Status area of the Signal tab reports when
the channel has switched to failover mode
Cleared
The specified Channel field in the Output
Status area of the Signal tab reports the
switch to failover mode as information
only (status indicator does not report an
alarm condition)
Summary of Contents for OpenGear DRA-8902 Series
Page 1: ...DRA 8902 Series Dual 12G 6G 3G HD SD Reclocking Distribution Amplifier User Manual...
Page 6: ......
Page 14: ...1 6 Introduction DRA 8902 Series User Manual Iss 02...
Page 36: ...4 8 DashBoard Menus DRA 8902 Series User Manual Iss 02...
Page 40: ...5 4 Specifications DRA 8902 Series User Manual Iss 02...