background image

16 • FDB-9649-LC

FDR-9647-LC, FDT-9648-LC, and FDB-9649-LC User Guide (v5.0)

SDI Connections

The FDB-9649-LC provides one BNC for the SDI input and one BNC for the SDI output. (

Figure 5.4

)

Figure 5.4  FDB-9649-LC (Right) — SDI Connections

Fiber Optic Connections

The FDB-9649-LC provides one fiber optic input and one fiber optic output. (

Figure 5.4

)

Figure 5.5  FDB-9649-LC (Bottom) — Fiber Optic Connections

Input Status LEDs

The FDB-9649-LC includes two LEDs that display the status of the SDI input signal activity and the status of the 
OPTO input signal activity. These LEDs are located near the fiber optic connectors. (

Figure 5.6

)

Figure 5.6  FDB-9649-LC (Right) — OPTO Status LEDs

Table 5.1

 describes the behavior of the OPTO and SDI LEDs.

Table 5.1  SDI IN 1 and SDI IN 2 LEDs

Status

Description

OPTO

Green

When lit green, this LED indicates there is a valid video signal on the OPTO IN port.

Red

When lit red, this LED indicates there is an invalid fiber optic input signal.

SDI

Green

When lit green, this LED indicates there is a valid SDI input signal on the SDI IN 
BNC.

Red

When lit red, this LED indicates there is an invalid SDI input signal.

Bottom

Top

SDI OUT

SDI IN

Bottom

Top

OPTO OUT OPTO IN

Bottom

Top

SDI

OPTO

Summary of Contents for GearLite FDB-9649-LC

Page 1: ...FDR 9647 LC FDT 9648 LC and FDB 9649 LC User Guide ...

Page 2: ...people that make things happen At Ross our employees are a special group Our employees truly care about doing a great job and delivering a high quality customer experience every day This code of ethics hangs on the wall of all Ross Video locations to guide our behavior 1 We will always act in our customers best interest 2 We will do our best to understand our customers requirements 3 We will not s...

Page 3: ...n this manual Safety Notices Refer to the Important Regulatory and Safety Notices document that accompanied your product Statement of Compliance This product has been determined to be compliant with the applicable standards regulations and directives for the countries where the product is marketed Compliance documentation such as certification or Declaration of Compliance for the product is availa...

Page 4: ...by a generous 3 year warranty and will be repaired without charge for materials or labor within this period See the section Warranty and Repair on page 19 for details Environmental Information The equipment may contain hazardous substances that could impact health and the environment To avoid the potential release of those substances into the environment and to diminish the need for the extraction...

Page 5: ...P O Box 880 Ogdensburg New York USA 13669 0880 General Business Office 1 613 652 4886 Fax 1 613 652 4425 Technical Support 1 613 652 4886 After Hours Emergency 1 613 349 0006 E mail Technical Support techsupport rossvideo com E mail General Information solutions rossvideo com Website http www rossvideo com ...

Page 6: ......

Page 7: ...LC Documentation Conventions Special text formats are used in this guide to identify parts of the user interface text that a user must enter or a sequence of menus and sub menus that must be followed to reach a particular command Interface Elements Bold text is used to identify a user interface element such as a dialog box menu item or button For example In the Edit dialog click Apply User Entered...

Page 8: ...el During business hours Eastern Time technical support personnel are available by telephone After hours and on weekends a direct emergency technical support phone line is available If the technical support person who is on call does not answer this line immediately a voice message can be left and the call will be returned shortly This team of highly trained staff is available to react to any prob...

Page 9: ...nt on the module you are using Features Each module includes the following standard features Supports major SDI formats up to 1080p 60Hz Supports DVB ASI EN 50083 9 Supports single mode fiber Re clocking on all outputs at 270Mbps 1 483Gbps 1 485Gbps 2 967Gbps and 2 970Gbps Input status indicator LEDs Small brick form factor 5V universal adapter with locking DC connector 3 year warranty FDR 9647 LC...

Page 10: ...10 Before You Begin FDR 9647 LC FDT 9648 LC and FDB 9649 LC User Guide v5 0 ...

Page 11: ...nd return loss specifications Figure 3 1 Simplified Block Diagram of FDR 9647 LC Functions Faceplate Overview The chassis faceplate provides a silk screen map of the connections available Figure 3 2 illustrates the FDR 9647 LC faceplate label Figure 3 2 FDR 9647 LC Faceplate Label POWER Connection The FDR 9647 LC includes a standard miniature power jack center pin positive that connects to the PS ...

Page 12: ...vior of the OPTO 1 and OPTO 2 LEDs SDI Connections The provides a BNC for one SDI input and one BNC for the SDI output Figure 3 6 Figure 3 6 FDR 9647 LC Left SDI Connections Table 3 1 OPTO 1 and OPTO 2 LEDs Status Description OPTO 1 Green When lit green this LED indicates a valid video signal on the OPTO IN 1 port Red When lit red this LED indicates an invalid video signal on the OPTO IN 1 port OP...

Page 13: ...t jitter and return loss specifications Figure 4 1 Simplified Block Diagram of FDT 9648 LC Functions Faceplate Overview The chassis faceplate provides a silk screen map of the connections available Figure 4 2 illustrates the FDT 9648 LC faceplate label Figure 4 2 FDT 9648 LC Faceplate Label POWER Connection Each module has a standard miniature power jack center pin positive that connects to the PS...

Page 14: ...ic connectors Figure 4 6 Figure 4 6 FDT 9648 LC Right SDI Input Status LEDs Table 4 1 describes the behavior of the SDI IN 1 and SDI IN 2 LEDs Table 4 1 SDI IN 1 and SDI IN 2 LEDs Status Description SDI IN 1 Green When lit green this LED indicates there is a valid SDI signal on the SDI IN 1 BNC Red When lit red this LED indicates there is an invalid SDI signal on the SDI IN 1 BNC SDI IN 2 Green Wh...

Page 15: ...lk screen map of the connections available Figure 5 2 illustrates the FDB 9649 LC faceplate label Figure 5 2 FDB 9649 LC Faceplate Label POWER Connection The FDB 9649 LC has a standard miniature power jack center pin positive that connects to the PS 9000 power supply This PWR jack is in the same location on each module regardless of the module type Figure 5 3 Figure 5 3 FDB 9649 LC Right Side PWR ...

Page 16: ...ty and the status of the OPTO input signal activity These LEDs are located near the fiber optic connectors Figure 5 6 Figure 5 6 FDB 9649 LC Right OPTO Status LEDs Table 5 1 describes the behavior of the OPTO and SDI LEDs Table 5 1 SDI IN 1 and SDI IN 2 LEDs Status Description OPTO Green When lit green this LED indicates there is a valid video signal on the OPTO IN port Red When lit red this LED i...

Page 17: ...wer adapter must be affixed in a similar manner as the chassis Other possible options include the use of adhesive magnetic sheets not included affixed to the chassis and the power adapter for removable mounting on metal cabinets etc Cable ties may be necessary in some applications to relieve strain on the mounting hardware and the connectors Surface Mount Strips The included VELCRO brand surface m...

Page 18: ...RO brand Surface Mount Strips 4 Press the chassis into position on the surface you want to mount it to Non Slip Pads Four non slip adhesive pads have been supplied for desktop placements Simply remove the protective backing film from the adhesive and affix one non slip pad to each of the four corners on the bottom of the chassis SURFACE MOUNT STRIPS PROTECTIVE BACKING FILM SERIAL NUMBER LABEL ...

Page 19: ...FDR 9647 LC FDT 9648 LC and FDB 9649 LC User Manual provides all pertinent information for the safe installation and operation of your RossGear Product Ross Video policy dictates that all repairs to the FDR 9647 LC FDT 9648 LC and FDB 9649 LC are to be conducted only by an authorized Ross Video Limited factory representative Therefore any unauthorized attempt to repair this product by anyone other...

Page 20: ...20 Warranty and Repair FDR 9647 LC FDT 9648 LC and FDB 9649 LC User Guide v5 0 ...

Page 21: ...083 9 Input Voltage 800mV nominal SDI Data Rates 270Mbps 1 5Mbps 3Gbps Impedance 75ohm Input Cable Equalization SD 100m HD 100m 3G 80m Return Loss 12dB all formats Table 8 2 Technical Specifications Fiber Optic Inputs Outputs Item Specifications Standards Accommodated SMPTE 259M SMPTE 292M SMPTE 424M DVB ASI EN 50083 9 Operating Wavelength Range 1310nm Input Power Operating Range Color Bars 3dBm t...

Page 22: ...wer Item Specifications Required Voltage 5v DC Power Consumption 5W Table 8 4 Technical Specifications Environment Item Specifications Thermal Environment 0 C to 40 C 32 F to 104 F ambient non condensing Table 8 5 Technical Specifications Dimensions Item Specifications Physical Dimensions 13cm x 4cm x 2cm 5 25 x 1 75 x 0 75 Weight 170g 6oz Table 8 2 Technical Specifications Fiber Optic Inputs Outp...