background image

 15 • Setup (Iss. 05)

Figure 6  

CMA-9011-R Front Edge User Controls

Figure 6

 shows all switches in the default UP (

) position. The DIP switches 

are number 1-8 starting at the left of the block. The top of the CMA-9011-R 
chassis includes a label that provides a condensed DIP switch settings chart. 
This chart is intended as a quick reference guide.

Note

 — 

SW1-7 

and 

SW1-8

 are not implemented and should be left in 

their default UP (

) position.

Table 1

 outlines how to set 

SW1-1 

to 

SW1-6

 and the following conventions 

are used:

  

Set the DIP switch in the UP position

Set the DIP Switch in the DOWN position 

Table 1  DIP Switch Positions

Video Standard

Chroma

VI

Setup

Mode

Setting 

Selections

SW1-1

SW1-2

SW1-3

SW1-4

SW1-5

SW1-6

NTSC (525)

PAL-N (625)

PAL-B/G (625)

Chroma On

Chroma Off

Pass VI

Blank VI

Setup On

Setup Off

Normal Mode

Color Bars

DIP Switches

1

3

4

2

5

6

7

8

ON

Summary of Contents for GearLite CMA-9011-R

Page 1: ...CMA 9011 R SDI Component Monitoring Amplifier with Reclocked SDI Outputs User Manual...

Page 2: ...people that make things happen At Ross our employees are a special group Our employees truly care about doing a great job and delivering a high quality customer experience every day This code of ethi...

Page 3: ...retrieval system or transmitted in any form or by any means mechanical photocopying recording or otherwise without the prior written permission of Ross Video While every precaution has been taken in t...

Page 4: ...ervicing instructions within the Product Manual Documentation Failure to heed this information may present a major risk of damage or injury to persons or equipment Warning The symbol with the word War...

Page 5: ...receptacles and point where they exit from the apparatus 7 Warning Indoor Use WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture 8 Do not block venti...

Page 6: ...the user will be required to correct the interference at his own expense Notice Changes or modifications to this equipment not expressly approved by Ross Video Limited could void the user s authority...

Page 7: ...e extraction and use of natural resources for its production It may contain hazardous substances that could impact health and the environment To avoid the potential release of those substances into th...

Page 8: ...7...

Page 9: ...re monochrome output 75 color bar pattern and vertical interval blanking The CMA 9011 R provides conversion of 525 and 625 SDI signals SMPTE 259M NTSC PAL and PAL N standards are supported The CMA 901...

Page 10: ...Four reclocked SDI outputs Reclocking to reduce jitter and noise Automatic input cable equalization 250m 820ft of Belden 8281 Color bar test signal with valid SDI input Excellent I O specifications Te...

Page 11: ...venient location However to ensure long life for this product observe the following precautions and operating requirements Maintain an ambient temperature of 20 C to 40 C Allow for air circulation aro...

Page 12: ...nstallation Option 3 Remove the Protective Backing Film from the other side of the VELCRO brand Surface Mount Strips 4 Press the chassis into position on the surface you want to mount it to Operating...

Page 13: ...te onto the bottom of the chassis Figure 3 using the screws provided in the Mounting Kit Do not use the screws removed during Step 1 Figure 3 Flat Metal Plate Installation Option 3 Install the chassis...

Page 14: ...13 Installation Iss 05 Figure 4 Angle Mounting Bracket...

Page 15: ...Installations outside of North America using line voltages of 200 240V require a plug certified for the country of use to be installed on the supplied line cord Refer to the section Important Regulato...

Page 16: ...rence guide Note SW1 7 and SW1 8 are not implemented and should be left in their default UP position Table 1 outlines how to set SW1 1 to SW1 6 and the following conventions are used Set the DIP switc...

Page 17: ...s Indicator LEDs Table 2 Status LED Descriptions LED Color Function STATUS Green When lit green this LED indicates that the CMA 9011 R is powered on and functioning correctly Flashing Green When flash...

Page 18: ...modated SMPTE 259M conversion at 270Mbps only Input Impedance 75ohm terminating Return Loss 19dB to 270MHz Equalization Automatic up to 26dB 250m of Belden 8281 cable 270Mbps Serial Video Output Numbe...

Page 19: ...quency Response 0 25dB to 5MHz typically 1dB 5 75MHz Differential Phase 1 Differential Gain 1 Outputs Short Circuit Protected Yes RMS Noise unweighted 53dB 0 5MHz Power Required Voltage 5V DC 5 regula...

Page 20: ...ser Manual of our Digital Products line provides all pertinent information for the safe installation and operation of your GearLite Product Ross Video policy dictates that all repairs to the GearLite...

Page 21: ...Service Information Iss 05 20 Notes...

Page 22: ...21 Service Information Iss 05 Notes...

Page 23: ...Service Information Iss 05 22 Notes...

Page 24: ...trade show information Visit Us Visit our website for Company information and news Related products and full product lines Online catalog Testimonials Technical Support Telephone 1 613 652 4886 After...

Reviews: