Ross Abekas AirCleaner ACL-A User Manual Download Page 5

Technical Support

At Ross Video, we take pride in the quality of our
products, but if a problem does occur, help is as close as
the nearest telephone.

Our 24-Hour Hot Line service ensures you have access
to technical expertise around the clock. After-sales
service and technical support are provided directly by
Ross Video personnel. During business hours (eastern
standard time), technical support personnel are available
by telephone. Outside of normal business hours and on
weekends, a direct emergency technical support phone
line is available. If the technical support personnel who
is on call does not answer this line immediately, a voice
message can be left and the call will be returned shortly.
Our Technical support staff are available to react to any
problem and to do whatever is necessary to ensure
customer satisfaction.

Abekas AirCleaner User Manual (v3.5) — Document Information •

v

Summary of Contents for Abekas AirCleaner ACL-A

Page 1: ...Abekas AirCleaner User Manual v3 5...

Page 2: ...Ross our employees are a special group Our employees truly care about doing a great job and delivering a high quality customer experience every day This code of ethics hangs on the wall of all Ross Vi...

Page 3: ...ce with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user w...

Page 4: ...and voltages that are exposed on the module receptacle connector inside the chassis Please keep fingers tools and foreign metal objects away from the exposed receptacle connector while the chassis ha...

Page 5: ...ness hours eastern standard time technical support personnel are available by telephone Outside of normal business hours and on weekends a direct emergency technical support phone line is available If...

Page 6: ...n Time 15 Trigger Stretch 15 Video Setup 16 Video Connections 16 Supported Video Formats 16 To Set the Video Reference Type 16 Audio Setup 17 Audio Connections 17 To Select the Audio Source for PGM IN...

Page 7: ...D Options All AirCleaner models support the Redundant Power Panic Button Control Panel and Panel Button Y Cable options Redundant Power Supply This option provides an additional power supply to guard...

Page 8: ...at In this example AirCleaner is programmed with the following parameters Screeners One Total PGM Delay 40 00 Video Reaction 1 2 00 On Video Trigger Defocus Defocus Ramp 0 00 This example begins at an...

Page 9: ...irst frame that was marked as the start of the violation is just one second away from triggering the system Time 44 00 One second later the first frame of the violation has arrived at the trigger poin...

Page 10: ...er another second the panic button release marker has reached the trigger point and if a defocus is being applied the real time defocus engine starts to fade out Time 53 00 One second later the aux in...

Page 11: ...enu User Memory Menu each allowing quick access to specific areas of system configuration or control When you exit the Options Menu or User Memory Menu you are taken back to the first item on the Main...

Page 12: ...the PGM IN BNC AUX Video IN audio video outputs are locked to the SDI video signal present on the AUX IN BNC Bi Lvl REF IN audio video outputs are locked to the Bi Level sync analog video signal pres...

Page 13: ...orted All screeners share the total delay time provided by the system 1 Use the SELECT knob to select Screeners 2 Use the SET to select the number of screeners One the total program delay is applied t...

Page 14: ...usts the offset applied to the audio relative to video in tenths of a second to correct synchronization errors 1 Use the SELECT knob to select PGM Audio Offset 2 Use the SET knob to select the amount...

Page 15: ...he Audio panic button To Set the Audio Reaction Time This allows the system to compensate for the amount of time it takes for a screener to hear a violation and press the panic button The inpoint for...

Page 16: ...system switches to when the video panic button is pressed The system can be set to use a defocus instead of the aux video The embedded audio from this video source can also be used TAP OUT the monitor...

Page 17: ...GM In AES the 4 PGM IN AES audio BNCs SDI Embedded the embedded audio in the PGM IN SDI video signal on the PGM IN BNC 4 Use the SELECT knob to select Save Changes and press the SET knob to select OK...

Page 18: ...lding the video panic button you can adjust the amount of defocus 4 Defocus Only Use the SELECT knob to select Defocus Ramp a Use the SET knob to select the amount of time to fade the defocus effect i...

Page 19: ...ob to select the memory register you want to save the setup to 3 Press SAVE and OK to save the setup to the selected memory register 4 Use the SELECT knob to select Finished and press the SELECT knob...

Page 20: ...ur facility Note The AirCleaner does not support DHCP 1 Open a web browser and navigate to the IP address of the AirCleaner 2 Enter the new network settings in the IP Address Subnet Mask and Gateway f...

Page 21: ...e settings when the system left the factory 1 From the Main Menu use the SELECT knob to select Options Menu and press the SET knob 2 Use the SELECT knob to select Factory Defaults and press the SET kn...

Page 22: ...on HD SMPTE 292M 10 bit at 1 5Gb s serial digital Video Inputs SDI SD SMPTE 259M 10 bit at 270Mb s serial digital Value Specification HD 16 Tracks AES EBU 48kHz at 24 bit 8 Tracks 4 stereo pairs per P...

Page 23: ...Manual Bypass Switch 5 Tally 1 Manual Bypass 6 Tally 2 External Lamp 7 Tally Common 8 Ground 9 Pins 5 Bypass Button and 1 Tally 1 are tied to the Manual Bypass button on the front of the AirCleaner ch...

Page 24: ...tions 20 O Operating Temperature 22 Operation 8 Options 7 Overview 7 P Panic Button 18 Panic Button Control Panel Y Cable 7 PGM IN 16 PGM IN Audio 17 PGM OUT 16 PGM OUT Audio 17 R Reaction Time Settin...

Reviews: