Approved Manufacturing Locations
Emerson Process Management - Rosemount Inc. — Chanhassen, Minnesota, USA
Emerson Process Management — Wessling, Germany
Emerson Process Management Asia Pacific Private Limited — Singapore
Emerson Process Management — Beijing, China
Emerson Process Management — Daman, India
Emerson Process Management — Sorocaba, Brazil
European Directive Information
The EC declaration of conformity can be found on page 22. The most recent revision can
be found at www.emersonprocess.com.
Ordinary Location Certification for Factory Mutual
As standard, the transmitter has been examined and tested to determine that the design
meets basic electrical, mechanical, and fire protection requirements by FM, a nationally
recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety
and Health Administration (OSHA).
Hazardous Locations Certifications
North American Certifications
Factory Mutual (FM)
E5
Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof for
Class II, Division 1, Groups E, F, and G. Dust-Ignition-Proof for Class III, Division 1.
T5 (Ta = 85 °C), Factory Sealed, Enclosure Type 4x
I5
Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D; Class II,
Division 1, Groups E, F, and G; Class III, Division 1 when connected per Rosemount
drawing 03031-1019; Non-incendive for Class I, Division 2, Groups A, B, C, and D.
Temperature Code:T4 (Ta = 70 °C), T5 (Ta = 40 °C),
Enclosure Type 4x
For input parameters see control drawing 03031-1019.
Canadian Standards Association (CSA)
All CSA hazardous approved transmitters are certified per ANSI/ISA 12.27.01-2003.
E6
Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof for
Class II and Class III, Division 1, Groups E, F, and G. Suitable for Class I, Division 2
Groups A, B, C, and D. Enclosure Type 4X, factory sealed; Single Seal. Class I Zone
1 Ex d IIC T5.
C6
Explosion-Proof and Intrinsically Safe approval. Intrinsically Safe for Class I, Division
1, Groups A, B, C, and D when connected in accordance with Rosemount drawings
03031-1024. Temperature Code T3C; Single Seal.
Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof for
Class II and Class III, Division 1, Groups E, F, and G. Suitable for Class I, Division 2
Groups A, B, C, and D hazardous locations. Enclosure type 4X, factory sealed; Single
Seal.
4051 RevBA.fm Page 17 Monday, June 22, 2009 3:15 PM
Summary of Contents for 3051
Page 22: ...Quick Installation Guide 00825 0100 4051 Rev BA June 2009 Rosemount 3051 22 DOC ...
Page 23: ...Quick Installation Guide 00825 0100 4051 Rev BA June 2009 Rosemount 3051 23 ...
Page 24: ...Quick Installation Guide 00825 0100 4051 Rev BA June 2009 Rosemount 3051 24 ...
Page 25: ...Quick Installation Guide 00825 0100 4051 Rev BA June 2009 Rosemount 3051 25 ...
Page 26: ...Quick Installation Guide 00825 0100 4051 Rev BA June 2009 Rosemount 3051 26 NOTES ...
Page 27: ...Quick Installation Guide 00825 0100 4051 Rev BA June 2009 Rosemount 3051 27 NOTES ...
Page 28: ...Quick Installation Guide 00825 0100 4051 Rev BA June 2009 Rosemount 3051 28 ...