www.rosemount.com
Reference Manual
00809-0100-4030, Rev DA
June 2007
Rosemount 2120
A
PPENDIX
A
R
EFERENCE
D
ATA
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-5
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-8
Specifications
Physical
Product
Rosemount 2120 Liquid Level Switch
Measuring principle
Vibrating Fork
Applications
Most liquids including coating liquids, aerated liquids, and slurries
Mechanical
Housing/Enclosure
Connections
See “Process Connection Size / Type” on page A-8
Extended Lengths
Available as standard to a maximum 118-in. (3000 mm), other on request
Process Material
316L Stainless Steel (1.4404), Hastelloy C or Halar (ECTFE) / PFA co-polymer coating (39.37-in. [1000
mm] max). Hand polished to better than 0.8
μ
m option available for hygienic connections. Gasket material
for
3
/
4
-in. and 1-in. BSPP (G) is Non-asbestos BS7531 Grade X carbon fiber with rubber binder.
Dimensional Drawings
See “Dimensional Drawings” on page A-5
Housing Code
A
D
X
Y
S
T
Housing material
Nylon PA66 30%GF
Al alloy ASTM B26
356-T6, LM25 TF, or
A360.0
316C12 Stainless Steel
LED Window
PMMA
none
none
Conduit Entry
M20
1
/
2
-in. NPT
M20
3
/
4
-in. NPT
M20
3
/
4
-in. NPT
Ingress Protection
IP66/67 to EN60529
IP66/67 to EN60529,
NEMA 4X
IP66/67 to EN60529,
NEMA 4X
Summary of Contents for 2120
Page 2: ......
Page 4: ...Reference Manual 00809 0100 4030 Rev DA June 2007 Rosemount 2120 ...
Page 8: ...Reference Manual 00809 0100 4030 Rev DA June 2007 Rosemount 2120 TOC 4 ...
Page 68: ...Reference Manual 00809 0100 4030 Rev DA June 2007 Rosemount 2120 B 20 ...
Page 69: ......
Page 70: ......
Page 71: ......