background image

 

11 

ULTRAMATRIX AV HD INSTALLATION AND OPERATIONS MANUAL

 

 

The Button Panel

: These are the numbered buttons across the top and left sides. Click an output button on 

the top, and then click an input button on the left.  
 
Options for using the Button Panel: 
 

 

Output Options

: To select multiple outputs next to each other, click on one output, then hold the shift key 

down and click the last output. When the input is clicked, it is routed to all selected outputs. To select 
multiple outputs individually, hold the control key down and click on any number of outputs. When the input 
is clicked, it is routed to all selected outputs.  

 

 

Input Options

: To route an input to all the outputs at once, hold the control key down and click on an input. 

To leave the outputs selected after the route is made, hold the shift key down and click on an input.  
 
 

 

Macros

: This section of the window is used to save and play back macros. Macros store a set sequence of 

routes.  
 
To record a macro:  
 
1.  Click on the Record button (last button shown). A blinking “recording” message below this button will be 

displayed to indicate that all routes are being recorded.  

2.  Select the desired crosspoints. There is no limit on the number of routes you may record.  

3.  If you click a macro button while in the record mode, the macro will be executed, and these routes will be 

added to the recording. This makes it possible to combine the routes of two or more macros into one bigger 
macro.  

4.  When finished, click the “Save Macro” button. You will be instructed to then click on one of the macro 

buttons. Doing this will save the recorded routes to that button. To cancel saving the macro, click the 
“Cancel Save” button.  

5.  To play back a macro, simply click on one of the 50 macro buttons. Use the scroll bar to bring any of these 

into view.  

6.  The macros are automatically saved in the current configuration file. They are also saved when you select 

the File/Save Configuration... menu. To save macros in a separate file for a special purpose, select the 
File/Save Macros...menu.  

 

Summary of Contents for UltraMatrix AV HD

Page 1: ...UltraMatrix AV HD 16x16 HDMI VIDEO MATRIX SWITCH 10707 Stancliff Road Phone 281 933 7673 Houston Texas 77099 www rose com INSTALLATION AND OPERATIONS MANUAL ...

Page 2: ......

Page 3: ...ERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO A PERIOD OF ONE YEAR FROM THE DATE OF PURCHASE AND NO WARRANTIES WHETHER EXPRESS OR IMPLIED WILL APPLY AFTER THIS PERIOD SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU IF THIS PRODUCT IS NOT IN GOOD WORKING ORDER AS WARRANTED ABOVE YOUR SOLE REMEDY...

Page 4: ... be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada Operation is subject to the following two c...

Page 5: ...he IP address on the UMA 16Hx16H RCI 14 Figures Page Figure 1 System Application Overview 4 Figure 2 Connection Diagram 5 Figure 3 Front Panel Buttons 6 Figure 4 UltraMatrix AV HD Default Display 6 Figure 5 Main Menu 7 Figure 6 EDID Input Display 7 Figure 7 RoseControl Configuration Screen 8 Figure 8 Main Routing Window 9 Figure 9 Routing Window Modified Connections 10 Figure 10 Connecting the Net...

Page 6: ...eo sources and destination monitors to the unit 2 Installing the access software for controlling the UltraMatrix AV HD Each video source is connected to one of the sixteen video in HDMI connectors using a HDMI to HDMI cable Disclaimer While every precaution has been taken in the preparation of this manual the manufacturer assumes no responsibility for errors or omissions Neither does the manufactu...

Page 7: ...provals FCC CE RoHS Compliant Power Supply Approvals UL CE CSA CEC RoHS Environmental Operating Tempratures 0 to 40 C 32 to 104 F Operating Humidity 10 to 85 Non condensing Storage Temprature 20 to 60 20 to 140 F Storage Humidity 10 to 85 Non condensing IMPORTANT Each input and output can support up to 10mA 5VDC Do not connect extenders that are powered by HDMI Package contents 1304584334582_6 doc...

Page 8: ...sentations Financial Remote servers Call Centers for Technical Support Industrial Long Range Workstation Isolation Airport Installations Air Traffic Control Passenger Information Medical Remote viewing away from Sensitive Magnetic Equipment Recording for Large Studios where Editing Mixing Stations are Compact and or Require Compete Silence ...

Page 9: ...displays Connect the male to male HDMI extension cables to the input devices and to the IN ports on the UltraMatrix AV HD Connect the displays to the OUT ports on the UltraMatrix AV HD Connect the power cord and power on the UltraMatrix AV HD Power on the input devices and the displays Figure 2 Connection Diagram ...

Page 10: ...see a list of ports on the front panel display Figure 4 UltraMatrix AV HD Default Display To assign an output to an input press SWITCH A blinking block cursor will appear Use UP and DOWN to select the input that you would like to assign Once the cursor is over the desired input port press ENTER to enter editing mode Press UP and DOWN to select the output port Once you have selected an output press...

Page 11: ...n the configuration is changed via the front panel or remote control optional Memory Save Sets the UltraMatrix AV HD to save the configuration when powered off Display Input Status This displays the status of the inputs If no input is present the display will read NONE This is the default view Restore Factory Settings Sets the UltraMatrix AV HD to the default factory configuration Manage EDID Give...

Page 12: ...elp File UltraMatrix AV HD Manual in PDF format Double click RoseControl_Installer exe in order to initiate software installation Click Install After installation has completed click CLOSE In order to use the software click on the START button Programs RoseControl There you should see a help file the RoseControl launcher as well as a shortcut to uninstall RoseControl Click on RoseControl in order ...

Page 13: ... commands almost instantly After you have entered the necessary information click OK This will now take you to the Main Routing Window where you can route the different HDMI connections Figure 8 Main Routing Window On this screen you will notice the input buttons running down the left side while the output buttons run across the top They are labeled 1 through 16 The Main Routing Window enables you...

Page 14: ...s Simply click on the cross point itself The input on the left will then be routed to the output above Note Inputs can be routed to several different outputs but each output can only have a single input at any one time So you can have several connections horizontally but not vertically Figure 9 Routing Window Modified Connections ...

Page 15: ...acros store a set sequence of routes To record a macro 1 Click on the Record button last button shown A blinking recording message below this button will be displayed to indicate that all routes are being recorded 2 Select the desired crosspoints There is no limit on the number of routes you may record 3 If you click a macro button while in the record mode the macro will be executed and these rout...

Page 16: ...ginal container or equivalent insured and shipped to Rose Electronics Attn RA__________ 10707 Stancliff Road Houston Texas 77099 USA Technical Support If you are experiencing problems or need assistance in setting up configuring or operating your product consult the appropriate sections of this manual If however you require additional information or assistance please contact the Rose Electronics T...

Page 17: ...t might cause damage to them Use only power cords and connection cables designed for this Unit Use only a grounded three wire electrical outlet Keep objects that might damage this Unit and liquids that may spill clear from this Unit Liquids and foreign objects might come in contact with voltage points that could create a risk of fire or electrical shock Operate this Unit only when the cover is in ...

Page 18: ... Connect the unit s RJ45 port to a computer configured with an Ethernet card and Window s operating system XP or Vista Use a network cable to connect the computer to unit Figure 10 Connecting the Network Cable 2 Access the control panel network tab on the computer being used to configure the unit and change the existing IP address to 192 168 1 25 and the IP network mask to 255 255 255 0 This chang...

Page 19: ... network settings for the unit in the Network Setting page Figure 13 RoseControlIP Network Setting page 7 Enter the desired IP address and network mask for the unit and click the Activate button to apply the entered settings 8 The unit is now ready to be placed on the general network Disconnect the unit from the computer and connect it directly to the network Restore the previous IP address of the...

Page 20: ...10707 Stancliff Road Phone 281 933 7673 Houston Texas 77099 WWW ROSE COM ...

Reviews: