Storage & Shipment

Before storing the machine for an extended period of time, ensure the following:
•  Fluid bottle has been removed and securely capped
•  Proper cleaning of exterior as described above
•  Proper purging of the heat exchanger as described above
•  Machine is properly boxed or covered to avoid dust build up on internal components
•  If shipping, use original packaging or comparable protection to avoid damaging the machine 
 

in transit

SPECIFICATIONS

Physical
Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24.16” (613.8 mm)
Width.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 11.54” (293 mm)
Height  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.40” (289.5 mm)
Dry weight    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   32 lbs (14.5 Kg)
Performance
Operating time     .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . continuous
Warm up time  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-10 minutes
Control and programming
Control options  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DMX, timer remote
DMX channels  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Fluid system
Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120v - 4 liters / 240v - 5 liters
Fluid consumption  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.9 liters/hour
Compatible fluids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V-Hazer fluid ONLY
Connections
DMX    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   5 pin XLR
Remote / Multi-Link     .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   3 pin XLR
AC power  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Fixed power cable
Electrical
AC voltage   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120V / 230V, 50/60Hz
Main fuse (120V US version)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10AT
Main fuse (230V EU version)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5AT
Thermal
Maximum ambient temperature    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   40°C (104°F)
Exterior surface temperature, steady state, at 20°C ambient  . . . . . . . . . . . . . . . . . . . . 40°C (104°F)
Approvals
European EMC: . . . . . . . . . . . . . . . . . . . . . . . . . EN61000-6-3,EN61000-3-2,EN61000-3-3,EN50366
European safety: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  EN 60 335-1
Immunity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN61000-6-1, EN61000-4-2,EN61000-4-3
ETL approvals (cETLus) pending . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL60335-1, CSA-E60335-1
Information in this document is subject to change without notice and does not represent a commitment on 
the part of Rosco Laboratories, Inc.

Summary of Contents for V-Hazer

Page 1: ...www rosco com V Hazer Fog Machine Operating Instructions READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...emote Control Panel 8 DMX Control 8 Multi Link 8 Using the Remote Control Panel 8 Using Timers 9 Using DMX Control 9 11 Connecting the DMX 9 Setting the DMX Address 10 DMX Operation 10 11 Using Multi...

Page 3: ...Rosco V Hazer Fluid All Rosco Fog and Haze Fluids are unique water based formulations that contain no petroleum distillates and are safe when used according to instructions The operating temperature p...

Page 4: ...machine that shows signs of improper use Even slight damage may be an indication of a major problem If the machine looks questionable use it only under strict observation If the machine shows any unu...

Page 5: ...e machine switched on for prolonged periods of time without producing haze Do Not Enclose the machine Do Not Install the machine in such a fashion that the operator cannot see the whole machine includ...

Page 6: ...ff by controlling the flow of power to the unit Air Input Purge Connection This is a push to connect inlet that accepts OD tubing and allows com pressed air to blow through the heat exchanger for clea...

Page 7: ...led if Standby mode is engaged Fog Level Knob Rotate to set the desired amount of haze output Higher numbers indicate more haze Output is controlled by pump speed increasing and sending more haze flui...

Page 8: ...ap along the tube and tighten the cap onto the bottle Take precautions to avoid fluid spills All Rosco fog and haze machines are primed at the factory with a small amount of fluid No additional primin...

Page 9: ...ne on and off using Standby mode and set a repeating timed cycle of on off operation DMX Control from your lighting desk is available as a standard option The V Hazer will use 2 channels of DMX contro...

Page 10: ...haze before stopping The numeric settings on the timer knobs are relative settings and do not correspond to specific seconds or minutes See the table below for an approximation of the time duration co...

Page 11: ...fect with its internal fan speed set to maximum and the output volume adjusted to achieve the desired density of haze However with DMX control an effects designer can fully customize the haze effect b...

Page 12: ...the daisy chain from the remote of the Head Machine to the final machine is 165 feet 50 m Note It is possible to use the Remote Control Panel even when the machine is set up and addressed for DMX Oper...

Page 13: ...level received via DMX DMX interference due to non terminated signal Raise the DMX level to 11 100 Review the chart in the DMX Operation section of the manual Contact nearest Service Center for repai...

Page 14: ...re optimal performance The Air Input Connection was designed to provide a fast and efficient method of cleaning the heat exchanger by purging it of residual fluid and build up using compressed air For...

Page 15: ...rol and programming Control options DMX timer remote DMX channels 2 Fluid system Capacity 120v 4 liters 240v 5 liters Fluid consumption 0 9 liters hour Compatible fluids V Hazer fluid ONLY Connections...

Page 16: ...15 Dimensions Dimensions are shown in inches and millimeters...

Page 17: ...ver damage to the Rosco product caused by parts not manufactured distributed or certified by Rosco Rosco is not obligated to provide warranty service should the product fail to be properly maintained...

Page 18: ...and light Industrial environments 60335 1 2002 A15 2011 Safety of household and similar electrical appliances BS EN 62233 2008 Electromagnetic fields These standards reference the following European s...

Reviews: