background image

51-17568   REV B 

 

16

the camera overlay off. If actuated again when in OFF mode, the overlay appears in the 
upper left position, and the cycle starts over. 
 
Each new setting is saved in the flash memory of the microcontroller interface and the 
overlay position is retained through power cycles. 
 
Upon power up the camera overlay will display the current mode of operation (e.g. 
BIPOLAR).  After all settings are displayed the camera overlay will go off. 
 

 
NOTE:

 Even in the OFF mode, the overlay will automatically be activated when the user 

enters LLA adjust mode (in the upper left corner). As soon as the new LLA value has been 
set, the overlay will be turned off automatically. 
 
 

Summary of Contents for CE-X-36

Page 1: ...36 1 COLOR ZOOM CAMERA OPERATION AND MAINTENANCE MANUAL SERIAL NUMBER __________ SALES ORDER __________ 5618 Copley Drive San Diego CA 92111 7902 TEL 858 565 8500 FAX 858 565 8808 www rosys com 51 175...

Page 2: ...SELECTION 7 2 9 1 Mode Selection 7 3 CAMERA OPERATION 11 3 1 GENERAL 11 3 2 INSTALLATION 11 3 3 EXPOSURE CONTROL 11 3 4 ZOOM CONTROL 12 3 5 FOCUS CONTROL 12 3 6 IMAGE FLIP CONTROL 13 3 7 NEGATIVE COL...

Page 3: ...5 1 GENERAL 19 5 2 CAMERA DISASSEMBLY 20 5 3 CAMERA OPERATIONAL CHECKS 20 5 4 CAMERA TROUBLESHOOTING 21 6 MAINTENANCE 22 APPENDIX 23 51 17568 REV B III...

Page 4: ...his warranty shall be governed by the laws of the State of California In the event the defect is determined to be within the terms of this warranty then ROS agrees to repair and or replace at ROS disc...

Page 5: ...nstallation and or operation of these products If you have any questions or problems with this product that are not covered by this manual or instruction please contact our agent in your area or conta...

Page 6: ...CHANGE RECORD REV DESCRIPTION DATE A Initial Release 17JAN08 BAL B SEE EC 02192 10FEB15 SW 51 17568 REV B VI...

Page 7: ...drawings in the appendix The camera housing is constructed of hard anodized aluminum and is designed to be operated in natural but hostile environments The front window is made of impact resistant op...

Page 8: ...application of power with reversed polarity In addition circuits on this board generate the camera control commands sent to the zoom camera module in order to achieve control of Focus position Zoom po...

Page 9: ...length 0 to 5 000 ft 0 to 1524m of RG 59 U or equivalent balanced line cable Zoom Range 36 1 optical 3 4 to 122 4 mm focal length Digital Zoom 12x 432x with optical zoom combined Field of View In Air...

Page 10: ...Housing Hard Anodized Aluminum Viewing Port Polished Acrylic 2 6 ENVIRONMENTAL Operating Temperature 0 C to 50o C 32 F to 122 F Storage Temperature 20o C to 60o C Depth Rating 70 m 230 ft 2 7 STANDAR...

Page 11: ...9 BCR Endbell Connector Impulse MHDG 9 BCR Inline Mating Connector Impulse MHDG 9 CCP Right Angle Mating Connector Impulse MHDG 9 CCP RA 1 Figure 4 Impulse MHDG 9 BCR 2 7 4 Impulse MSSJ 10 BCR Endbel...

Page 12: ...l or any device that can send RS485 messages On these cameras all of the operating functions including focus zoom and exposure can be controlled from the computer through two conductors utilizing stan...

Page 13: ...or 12V applied to pin 9 for Focus Far Differential 2 line This mode requires simultaneous application of a voltage source both and across two camera input pins For example if the source typically 12 V...

Page 14: ...switch assemblies on the board labeled S1 and S2 S1 has 8 and S2 has 6 individual switches The ON position is indicated on each switch assembly A tabulation that follows shows the positions of switche...

Page 15: ...51 17568 REV B 9...

Page 16: ...BIPOLAR INPUTS SELECTION UNIPOLAR OR DIFFERENTIAL INPUTS S1 1 3 2 8 6 5 4 7 S2 ON 1 3 2 5 4 6 ON S1 1 3 2 8 6 5 4 7 S2 ON 1 3 2 5 4 6 ON SELECTION UNIPOLAR OR DIFFERENTIAL INPUTS 3 2 1 S1 ON 7 4 5 6...

Page 17: ...on To achieve this wide range the camera achieves Exposure Control through composite operation of the iris video gain and shutter modes For most operations automatic exposure mode is used to optimize...

Page 18: ...on specific objects operation in a Manual Focus Mode may be required This is achieved by momentarily operating the Focus switch on the remote control unit To restore Automatic Focus Control simultaneo...

Page 19: ...area like a crack To activate or deactivate this function EXP DEC 12Vdc and FOCUS FAR 12Vdc must be toggled simultaneously As a way of visual acknowledgement whenever this function is activated or de...

Page 20: ...o access the control 3 9 1 Adjust LLA in Bipolar Unipolar Differential mode Adjusting the LLA is a simple 3 step procedure Step 1 Enter the LLA adjust mode This is performed by simultaneously actuatin...

Page 21: ...When the LLA adjust mode is exited the video the new setting is saved in the flash memory of the microcontroller interface and the value is retained through power cycles NOTE The LLA setting is saved...

Page 22: ...and the overlay position is retained through power cycles Upon power up the camera overlay will display the current mode of operation e g BIPOLAR After all settings are displayed the camera overlay wi...

Page 23: ...ere current overload but then unlike a fuse closes automatically once circuit conditions return to normal 4 1 3 Power Conditioning Capacitor C9 provides filtering of the input power before it is prese...

Page 24: ...ncludes a schematic of the video amplifier driver stages The video signals from the camera module are received through J3 6 The signals are applied to one side of capacitor C18 through the gain contro...

Page 25: ...of equipment to connector J2 As described earlier most of the logic inputs to the microcontroller are received from the inverters in device U1 The microcontroller responds to these inputs in achievin...

Page 26: ...e coax for continuity This is normally Pin 2 on the standard connector and exits the ROS controller on the middle pin of the BNC connector on the rear panel Normal resistance should only be a few ohms...

Page 27: ...st points to assist in troubleshooting circuits on the board TP6 Black near J6 is the common for all measurements Readings should be as follows Test Point Function Voltage TP1 Red Regulated Power 9 8...

Page 28: ...tted and all cabling is secured All threads should be carefully inspected for burrs or early signs of galling Small areas of damaged threads may be polished to remove any offending material The thread...

Page 29: ...APPENDIX CE X 36 1 CAMERA DRAWINGS 51 17565 Top Assembly CE X 36 1 51 17566 Installation CE X 36 1 51 17567 Wiring Diagram CE X 36 1 52 26634 Protocol RS485 Communication UIB 51 17568 REV B 23...

Reviews: