These guidelines are subject to change. Please check with ROPV to ensure that
the User Manual is the latest version for the vessel model being used.
•
Mount vessel using strap/saddle hardware provided and span recommended in
the engineering drawing.
•
Do not over tighten the straps – vessel must be allowed to expand under
operation.
•
Maximize the connection flexibility to allow for vessel growth under pressure.
•
Align the side ports with the system manifold, correcting any misalignment before
final installation.
•
Provide overpressure protection in the system safety devices.
•
Inspect end closures regularly for signs of corrosion. Immediate corrective action
and/or replacement is suggested in case of corrosion.
•
Relieve system pressure before working on the vessel.
•
Do not attempt to over-tighten the Permeate Port connections as this may
damage the end closure. One turn past hand tight should be sufficient.
•
Ensure that the Trust Cone is installed on the downstream end of the vessel.
•
Never operate the vessel in excess of its ratings. This may void the warranty and
cause bodily or property damage.
•
Do not operate the vessel permeate port over 125PSI.
•
Flush the vessel with permeate before system shutdown to reduce the chance of
corrosion.
•
Do not install the vessel in direct sunlight.
•
Operate the vessel within the recommended pH range - Operating pH Range: 3 –
11, Cleaning pH Range: 2 – 12 (less than 30 minutes).