background image

19 

TF 200.02.0026_eng 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 

 

 

 

 
 

Place 

2x M6 nuts

 into the profile and fix the bracket for the siphon with 

2x M6x12

 
 

 
 

 

Push the siphon into the bracket and fasten the connecting pipe with strips through the two holes. 

 

Summary of Contents for Standard 40-14770

Page 1: ...POX 2022 Ropox StandardLine Washbasin 40 14770 40 14771 40 14772 40 14773 User manual and Mounting instructions This manual should always be in close proximity to the product TF 200 02 0026_eng 17 05 2022 ...

Page 2: ...INSTRUCTION 10 4 1 INSTALLATION INTERFACES 10 4 2 CONNECTION ADAPTERS 12 4 3 LIST OF COMPONENTS 13 4 4 INSTALLATION OF PRODUCT 16 4 5 CABLE DIAGRAM 24 5 FUNCTIONALITY TESTING 25 6 SAFETY IN USE 25 7 CLEANING 26 8 TROUBLESHOOTING 26 9 MAINTENANCE 27 9 1 SERVICE SCHEDULE 28 10 SPARE PARTS 29 11 ENVIRONMENTAL PROTECTION 29 12 ELECTROMAGNETIC COMPATIBILITY 30 12 1 SUITABLE ENVIRONMENTS 30 12 2 ADJACEN...

Page 3: ...understood before use Always keep this manual in close proximity of the product The use installation and service of this product must be in compliance with this manual to avoid accidents and serious personal injury Never use or handle this product in other ways specified in this manual as it can result in personal safety hazards and or cause damage to the product Persons installing and or using th...

Page 4: ...ance Cleaning and user maintenance shall not be made by children without supervision Do not use the product if it has defects or have become damaged before being repaired or replaced If the control box makes unusual noise or smells switch off the mains voltage immediately Take care that the cables are not damaged Unplug the mains cable on mobile equipment before it is moved The products must only ...

Page 5: ...ss Date of production Stock number Serial number Operating interval of electrically operated equipment The use of electrical height adjustable equipment can run at maximum 2 minutes followed by an 18 minute break Type BF applied part The product complies with IEC 60601 1 requirements to provide protection against electric shock Consult manual for important safety related information warnings and s...

Page 6: ...to 40 C Operation Relative humidity 20 to 80 non condensing Intended environments This product is to be used only in Professional Healthcare Environment Homecare Environment The device is not intended for use in special environments as defined by IEC 60601 1 2 Materials in contact with patient Washbasin Frame Mixer tap Synthetic marble composite Welded steel tube St 37 aluminum Chrome Accessories ...

Page 7: ... user do not experience any risk in case of loss of product function performance 3 5 Non clinical functions Height adjusting offers better ergonomics to the user 3 6 Clinical functions The product does not have any clinical functions 3 7 Product dimensions 40 14770 30cm range 40 14771 Height adjustment 700 1000mm ...

Page 8: ...8 TF 200 02 0026_eng 40 14772 Height adjustment 685 985mm 40 14773 Height adjustment 700 1000mm NB All dimensions are in mm ...

Page 9: ...h cable accessories As an alternative you can use a hand control with cable The washbasin is operated in the same way As soon as the button is released the washbasin will stop moving Warning The product should always be able to travel the full range of actuation without colliding with objects Failing to do so will compromise the product stability and introduce risk of squeezing body parts Special ...

Page 10: ... and rawlplugs suitable for the specific wall type Plumbing The drain is Ø32 1 and ends in an Ø32x88 5 drain elbow The water supply ends in 2 two 90 shut off valves with outside thread pointing upwards not included The maximum protrusion of the shut off valves and drain connection should be max 90mm 3 to allow for the covers The optimum location and orientation is as shown in green It is important...

Page 11: ...and outer covers to allow water and drain to be brought inside the frame If the height is adjusted correctly in relation to the adjustment screws see page 17 the height of the cut out in the outer cover mustn t be greater than 27mm The total height of the cut out should not exceed 50mm The piping outside the lifting unit must be fixed and should be brought inside the frame as shown Now connect the...

Page 12: ...666 15mm Pipe Water hose extensions Hose from washbasin Coupling piece Extra hose 1 2 1 2 Item no 97001662 1 2 x 1 2 0 5m steel Item no 97001123 1 2 x 1 2 1m plastic Item no 97001120 Drain adapters Drain from washbasin Adapter Installation in room not included No adapter needed Ø32 Ø32 Ø40 Item no 97001660 Ø40 Ø32 Ø50 Item no 97001661 Ø50 Drain extensions Drain hose from washbasin Coupler Extra dr...

Page 13: ...n 40 14770 036 Actuator bracket 1x 30 67636 Incl 30 65550 013 96000167 Flexi legs without spindle Adjustment screw Ferrule 2x 40 14770 017 Alu profile 622mm 1x 40 14770 028 Bracket for washbasin 1x 40 14770 026 Alu top plate 1x 40 14770 024 Outside cover 1x 40 14770 025 Inside cover 1x ...

Page 14: ...nut M10 Strips black 4 8 290mm 1x 2x 2x 2x 40 14770 043 Incl 40 14770 022 30 65500 003 30 65550 005 95010814 95170508 95011025 95170510 96000810 Mounting parts frame Top bracket Flat steel nut actuator mounting Flat steel nut leg section INSEX screw M8x14 Chamfered washer M8 INSEX screw M10x25 Chamfered washer M10 Sleeve for hole Ø9 1x 1x 2x 2x 6x 6x 4x 4x 2x 40 14708 099 Incl 95041250 95170512 96...

Page 15: ... 32 pipe 32x88 5 white PP Wafix elbow HT Nipple to 3 8 Strips black 4 8 290mm Prevex 100mm extension Plate screw Ø4 8x70 cross recess A2 Plate nut M6 INSEX screw M6x12 Bracket for siphon 1x 1x 2x 1x 2x 2x 2x 1x 1x 2x 2x 1x 40 15621 For 40 14771 Incl Insolation foam pad Standard Washbasin 1x 1x 97001582 For 40 14772 60cm Straight Support Washbasin 1x 40 15622 For 40 14773 Incl Insolation foam pad H...

Page 16: ...nel Warning Before use always make sure that mains cable and hand control cable will be able to travel freely without the risk of squeezing or disconnecting the product as result of the movement Caution When connected to the mains the product must be placed in a manner according to power outlets so that the operator will be able to disconnect the product during use in case of an emergency Standard...

Page 17: ...17 TF 200 02 0026_eng Unscrew the adjustment screws 68mm below the bracket Place the lifting unit on the wall and mark holes for screws Drill holes and use the enclosed rawlplugs 68mm ...

Page 18: ...18 TF 200 02 0026_eng Fix the unit to the wall If the wall is uneven or the unit needs be moved from the wall due to skirting boards use the spacers ...

Page 19: ...19 TF 200 02 0026_eng Place 2x M6 nuts into the profile and fix the bracket for the siphon with 2x M6x12 Push the siphon into the bracket and fasten the connecting pipe with strips through the two holes ...

Page 20: ...20 TF 200 02 0026_eng Assemble drain hoses water and power as shown on the picture Alternatively the water and drain are mounted in the floor ...

Page 21: ...026_eng Remove the protective foil and glue in the control on the top plate Plug the cable into the control box running through the frame as shown on the picture Perform a functionality test of the electrical system ...

Page 22: ...two rods Fix the outer cover onto the two rods with M4 lock nuts and washers Fix the wash basin to the unit with the accompanying bolts and fix the top plate to the unit Caution When mounting a porcelain washbasin an insolation foam pad MUST be placed between the washbasin and the unit It is recommended to grout around the washbasin ...

Page 23: ...6_eng Mount the rest of the drain and connect the water to the tap Move the unit to upper position and lift the inside cap to turn on the water Now pull the inside cap back down to the floor to finish the installation ...

Page 24: ... is a standard accessory that comes with the StandardLine Upon request it s possible to get the StandardLine with a handcontrol with a flexible cord as well This handcontrol allows easier control of the unit especially from range Cable diagram with both controls ...

Page 25: ...e washbasin in a manner excluding the risk of damage to people or property The person operating the StandardLine washbasin is responsible for avoiding damage or injury If the washbasin is used in publicly accessible locations where especially children or other persons with reduced observation capability may get near the StandardLine washbasin the person operating the washbasin must pay sufficient ...

Page 26: ...laving and sterilization beyond normal cleaning may change the product safety and function Problem Solution The washbasin does not move up or down when pressing the hand control Check if 230 V is connected and if the power is on The engine is connected to the control box The control is connected to the control box The actuator is overloaded NOTE For every 2 minutes of activity it needs 18 minutes ...

Page 27: ...resetting Check that the movement is even and smooth Make sure that the network cable is able to move freely Check that any water connection hoses and drain hoses are tight and functional Check that all cables are mounted correctly and are in order and undamaged After each the inspection the service schedule must be completed See Service schedule Note Failing to comply with periodic maintenance ma...

Page 28: ... Remarks Service and maintenance Serial no Date Signature Remarks Service and maintenance Serial no Date Signature Remarks Service and maintenance Serial no Date Signature Remarks Service and maintenance Serial no Date Signature Remarks Service and maintenance Serial no Date Signature Remarks Service and maintenance Serial no Date Signature Remarks ...

Page 29: ...andardLine unit 1 40 14776 1 8 Standard washbasin 60x42cm 60cm Straight Support Hospital washbasin 1 1 1 40 15621 2 97001582 40 15622 1 9 Oras Saga 3910F 1 97001706 11 Environmental protection The product is not intended to be disposed as municipal waste Proper disassembly sorting and disposal of components must be done by waste disposal professionals Part Disposal recommendation Wash basin Cerami...

Page 30: ...ing normally 12 3 Cables Cable component Length Power cable 3 2m Hand control spiral cable Approx 5m extended Warning Use of accessories transducers and cables other than those specified or provided by the manufacturer of this could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation 12 4 RF portable equipment Warni...

Reviews: