6. 

Performance test 

 
6.1 

Performance test, electrically operated frame 

 
After installation and prior to use, all anti pinch functions of FlexiElectric and VertiElectric must be 
tested. The test must be carried out by competent personnel. Subsequently the test shall be 
carried out at least once a year: 
 

Testing prior to connection of mains voltage: 

1.  Check that the mounting instructions have been observed. 
2.  Check that all cables have been connected correctly and that the plugs have been pressed 

home.  

3.  Check that there are no load on the FlexiElectric or VertiElectric frames. 
4.  Check that there is nothing preventing the FlexiElectric or VertiElectric from moving freely 

within the height adjustment range. 

 

Now connect mains voltage to the control unit and proceed as follows: 
 

5.  Check that LED on master Smartbox (No. 3) flashes with the number of connected 

Smartboxes. 

 

For every FlexiElectric the following tests must be carried out: 
 

6.  Press DOWN on the control switch, move the FlexiElectric frame to bottom position and 

check that the movement is even and smooth.  

7.  Press UP on the control switch, move the FlexiElectric frame to top position and check that 

the movement is even and smooth. 

 

Test of the safety between the FlexiElectric frames: 

 

8.  Safety strip (downwards movement) on every FlexiElectric must be tested – See also 

instructions in the FlexiElectric Manual 

9.  Move the first FlexiElectric to the top position, and the next FlexiElectric to the bottom 

position 

10.  Press UP on the control switch (next FlexiElectric) and let the frame move 2-5 cm upward. 

Now activate the safety strip on the first FlexiElectric by pressing it lightly. The frame must 
stop the upward movement, move 1-2 cm downward and stop. 

11.  Test the rest of the FlexiElectric frames according to these procedures to make sure that all 

risk of trapping has been tested and found safe. 

 

Test of the safety between the FlexiElectric frames and the above VertiElectric: 

 

12.  First perform a performance test according to the VertiElectric Manual on each unit 
13.  Test one FlexiElectric at a time by moving it upwards, pressing the safety stopplate on the 

above VertiElectric shall stop the upward movement, move 1-2 cm downward and stop. 

14.  Follow the above instructions to make sure that all combinations / trapping risk has been 

passed (refer to combination possibilities section 9) 

 

If all these tests are ok, the system of frames are ready for use.  

 
 

 
 

Summary of Contents for 30-69001-8

Page 1: ...Smartbox 30 69001 8 User Manual Mounting Instructions Keep always this folder with product PDF 5956 01 01 2011 ...

Page 2: ...xt to each In these situations the Smartbox system will remove eliminate the extra risk of trapping which is not covered by the standard Safety strips and safty stopplates Up to 4 FlexiElectric can be connected side by side with the use of the Smartbox Above this you can also connect up to 4 VertiElectric side by side This means that you can connect a maximum of 8 Smartboxes in one system To see y...

Page 3: ... 98002106 1 pc L 50 cm modular cord Pos 4 to controlbox 5 Communication cable 98002107 1 pc L 50 cm Din 7Polet plug Pos 5 to controlbox 6 Extension cable 98002008 1 pc L 250 cm male female plug Pos 6 to next smartbox Pos 3 11 Spiral extension cable 98002016 1 pc L 25 100 cm black to safety strip Between Pos 6 3 at the smartboxes Common parts 1 set 96000155 Adhesive pads 5 pcs Cable tidy strips 10 ...

Page 4: ... controlbox Din plug To controlbox handset 7 Connection of the control switch for the table 2 Connection of Safety strip 8 Led light to be used at power up and trouble shooting 9 Dip switch for Smartbox settings naming the Smartbox 3 Communication input from previous Smartbox Comm In 10 Dip switch indicates first and last Smartbox connected 6 Connection to next Smartbox Comm Out 12 Connection of t...

Page 5: ...plug To controlbox handset Antipinch connection to Smartbox From Smartbox Com out to Smartbox Com In Use cables pos 6 11 3 Part No 98002008 98002016 98002105 From Smartbox Com out to Smartbox Com In Not in use if this is the first Smartbox in the system From Smartbox Com out to Smartbox Com In Not in use if this is the last Smartbox in the system ...

Page 6: ...tric Smartbox OFF Smartbox No 4 VertiElectric Smartbox OFF Smartbox No 6 VertiElectric Smartbox OFF Smartbox No 8 FlexiElectric First Smartbox ON Smartbox No 1 FlexiElectric Smartbox OFF Smartbox No 3 FlexiElectric Smartbox OFF Smartbox No 5 FlexiElectric Smartbox OFF Smartbox No 7 2 4 6 8 1 3 Master 5 7 ON OFF ...

Page 7: ...also schematics page 8 4 2 Indicate Set first and last Smartbox in the system Pos 10 You need to tell the system how many Smartboxes you have in the system You have to indicate set the first and the last Smartbox in the system Use the DIP switch pos 10 by setting No 1 in ON position both on the first and also on the last Smartbox All other Smartboxes in the system has to be OFF See also schematics...

Page 8: ...3 Master Frst Smartbox ON Smartbox No 3 Master Last Smartbox ON Smartbox No 4 Last Smartbox ON Smartbox No 2 Smartbox OFF Smartbox No 4 First Smartbox ON Smartbox No 1 Smartbox OFF Smartbox No 3 Master Last Smartbox ON Smartbox No 2 2 4 6 3 1 Smartbox OFF Smartbox No 4 Smartbox OFF Smartbox No 6 ...

Page 9: ... the FlexiElectric frame to top position and check that the movement is even and smooth Test of the safety between the FlexiElectric frames 8 Safety strip downwards movement on every FlexiElectric must be tested See also instructions in the FlexiElectric Manual 9 Move the first FlexiElectric to the top position and the next FlexiElectric to the bottom position 10 Press UP on the control switch nex...

Page 10: ...ngs X 4 Flashes Numbers of Smartboxes variates from original X 2 8 Flash Indicates the number of connected Smartboxes at power up or when master Flexi 3 DIP switch Pos 10 switches from OFF to ON Communication error Stopping all movements on master Awaiting feedback Stopping all movements on this Smartbox Faulty DIP switch settings Stopping all movements on this Smartbox Number of Smartboxes variat...

Page 11: ... It is very important that the layout is according to this schematic and that the Smartbox has been installed according to this manual and the manuals for FlexiElectric and VertiElectric has been followed Arrows shows the extra risk of trapping that are covered by using this Smartbox Ex FlexiElectric No 3 will stop upwards movement if safetystopplate on Verti No 2 4 6 are activated or the Safety s...

Page 12: ...Side 12 6 7 8 9 10 11 12 13 14 15 16 17 18 2 4 6 8 3 5 4 6 5 3 4 5 3 2 4 3 6 6 2 4 5 3 4 3 1 4 6 1 3 2 4 6 3 1 4 6 5 3 2 4 6 1 3 4 6 8 3 5 2 2 4 6 1 3 8 4 6 8 3 5 ...

Page 13: ...9 20 21 22 23 24 25 26 27 28 29 30 31 32 4 3 5 1 4 6 3 5 1 2 4 6 5 7 3 4 6 8 3 5 1 4 6 8 3 5 7 4 6 5 7 3 4 6 1 3 5 2 4 6 3 5 1 2 4 6 5 7 3 8 2 4 6 5 1 3 8 2 4 6 5 7 3 8 4 6 8 3 5 1 2 2 2 4 6 3 5 7 8 8 4 6 1 3 5 ...

Page 14: ... 41 42 43 44 45 46 47 4 6 5 7 3 1 2 8 4 5 7 3 1 2 6 8 3 5 1 1 4 5 7 3 1 8 2 4 6 3 5 7 1 2 4 7 1 3 5 2 6 8 3 5 7 1 4 4 6 8 5 7 1 3 2 4 6 8 5 7 3 2 2 4 6 3 5 1 8 4 6 8 5 1 3 2 2 4 6 3 5 7 8 8 2 4 6 1 3 5 7 4 6 8 7 1 3 5 2 4 6 8 5 7 3 1 ...

Page 15: ...e responsibility that the following product 30 69001 Smartbox conform to the following directives and standards DIRECTIVES 73 23EEC Low voltage directive 89 336 EEC EMC Directive STANDARDS DS EN 60335 1 2002 DS EN 61000 6 1 2001 DS EN 61000 6 3 2001 ...

Page 16: ...1 Complaints We refer to our general Terms of sale and delivery on our homepage www ropox com ROPOX A S Ringstedgade 221 DK 4700 Naestved Tel 45 55 75 05 00 Fax 45 55 75 05 50 E mail info ropox dk www ropox com ...

Reviews: