Side 2
Contents:
1.
INTRODUCTION ................................................................................................................................................. 2
2.
LIST OF COMPONENTS.................................................................................................................................... 3
3.
CONNECTION OF SMARTBOX ....................................................................................................................... 4
3.1
Descriptions ................................................................................................................................................. 4
3.2
Connection of Smartbox to controlbox......................................................................................................... 5
3.3
Connection between Smartboxes.................................................................................................................. 5
3.4
Connection / naming of 8 Smartboxe in a system......................................................................................... 6
4.
INITIALIZING THE SMARTBOX .................................................................................................................... 7
4.1
Numbering the Smartbox on the 8 polet DIP switch (Pos. 9): ..................................................................... 7
4.2
Indicate / Set first and last Smartbox in the system (Pos 10): ...................................................................... 7
4.3
Perform Master reset: .................................................................................................................................. 7
5
EXAMPLES........................................................................................................................................................... 8
6.
PERFORMANCE TEST ...................................................................................................................................... 9
6.1
Performance test, electrically operated frame ............................................................................................. 9
7.
CLEANING AND MAINTENANCE ................................................................................................................ 10
7.1
Cleaning ..................................................................................................................................................... 10
8.
TROUBLE SHOOTING..................................................................................................................................... 10
8.1
LED indications ......................................................................................................................................... 10
9
COMBINATION POSSIBILITIES & TRAPPING RISKS ............................................................................ 11
10.
CE-MARKING.................................................................................................................................................... 15
11.
COMPLAINTS.................................................................................................................................................... 16
1.
Introduction
If you want to avoid unnecessarily risk of trapping when installing several Ropox electrical height
adjustable frames in one system, you can do so, by using our Smartbox. The intelligent anti-
trapping system can be used when you have more electrical frames mounted next to each.
In these situations the Smartbox system will remove / eliminate the extra risk of trapping which is
not covered by the standard Safety strips and safty stopplates.
Up to 4 FlexiElectric can be connected side by side with the use of the Smartbox. Above this you
can also connect up to 4 VertiElectric side by side. This means that you can connect a maximum of
8 Smartboxes in one system. To see your combination possibilities, please refer to section 9.
Smartboxes must only be used together with Ropox products, such as FlexiElectric, VertiElectric
or 4SingleElectric, and only when mounting and daily use are according to this manual, and the
relevant manuals for FlexiElectric, VertiElectric or 4SingleElectric. The Smartbox will only be used
if you have two or more units mounted close together, and in this situations you need one
Smartbox per Controlbox in the system.
The correct use, operation and inspection are decisive factors for efficient and safe performance.
Prior to assembly check that all parts have been provided. See list of components page 3.
This document must ALWAYS be kept with the product and have been read and understood
by the user