Side 10
7.
Cleaning and Maintenance
7.1
Cleaning
Smartbox must only be cleaned with a soft dry cloth
8.
Trouble shooting
8.1
LED indications
Master
Slave
LED
Description
X
X
No light
Everything is ok
X
X
Steady light
Safety strip activated, or fault on safety strip on this
Smartbox
X
1 Flash
Communication error
X
X
2 Flashes
Awaiting feedback from other smartboxes
X
X
3 Flashes
Faulty DIP switch settings
X
4 Flashes
Numbers of Smartboxes variates from original
X
2-8 Flash
Indicates the number of connected Smartboxes at power
up, or when master (Flexi 3 DIP switch (Pos. 10)
switches from OFF to ON.
Communication error:
Stopping all movements on master.
Awaiting feedback:
Stopping all movements on this Smartbox
Faulty DIP switch settings:
Stopping all movements on this Smartbox
Number of Smartboxes variates:
Stopping all UP movements on all Smartboxes (downward
is ok if the Safety strips is ok)
The frame must not be connected to the mains voltage during cleaning.
Do not flush electrical components with water.