Technical data
Page 36
RES-5007
Version 1
Analogue output
(Actual value)
Terminal 17+13
0…10 VDC, I
max
= 5 mA, electrically separated from the heating circuit
corresponding to 0…300 °C or 0…500 °C
Precision: ±1% plus 50 mV
Reference voltage
output
+10 VDC / ±5%, I
max
= 5 mA
Digital logic level
Terminals 5, 6, 7,
LOW (0 V): 0…2 VDC
HIGH (24 VDC): 8…30 VDC (Current consumption max. 6 mA)
galvanically separated from the heating circuit, protected against faulty polarisa-
tion
Alarm output
Terminal 18
U
max
= 30 VDC
I
max
= 200 mA
U
ON
< 2 V (saturation voltage)
galvanically separated from the heating circuit, short-circuit-proof.
Can be inverted through slide switch.
Power loss
Max. 20 W
Ambient conditions
Maximum altitude 2000 m
Ambient temperature: +5…+45 °C
Maximum relative humidity: 80% at temperatures up to +31 °C, decreasing line-
arly to 50% relative humidity at +45 °C
Degree of protection
IP 20
UL file
E464680
Mounting
When mounting the device, a surrounding safety dis-
tance of 20 mm (e.g. To other devices and wiring)
must be maintained.
When mounting on a horizontal top hat rail, the mov-
able latch, which is necessary for fastening, must face
downward.
When mounting on a vertical top hat rail, end holders must be installed on both
sides to fasten the controller mechanically.
Weight
Approx. 0,5 kg (incl. plug-in connector parts)
Housing material
Plastic, polycarbonate, UL-94-V0
Connecting cable
Type / cross-sections
Rigid or flexible; 0.2…2.5 mm² (AWG 24…12) through pluggable terminals
Pluggable terminals: Tightening torque: 0.5…0.6 Nm
(Screwdriver: SZS 0.6x3.5 mm)
If ferrules are used, they must be crimped in accordance with
DIN 46228 and IEC/EN 60947-1. Otherwise, correct electrical contact
in the terminals is not guaranteed.
!