![Ropex RESISTRON RES-5007 Operating Instructions Manual Download Page 20](http://html1.mh-extra.com/html/ropex/resistron-res-5007/resistron-res-5007_operating-instructions-manual_1486113020.webp)
Device functions
Page 20
RES-5007
Version 1
8.3
Temperature display (actual value output)
The RES-5007 sends to the terminals 17+13 an analogue signal 0…10 VDC, which is proportional to the real
ACTUAL temperature.
Voltage values:
0 VDC
0 °C
10 VDC
300 °C (ATR-3) or 500 °C (ATR-5), depending on the device configuration
The correlation between the change in the output voltage and the ACTUAL temperature is linear.
A display instrument can be attached to this output for visualisation of the heating element temperature.
The ROPEX temperature display ATR-x in its overall characteristics (size, scaling, dynamic behaviour) is optimally
suited for this use and can be used for this, if needed (
section 13 "How to order" on page 38).
With this display, not only can TARGET-ACTUAL comparisons be made, but other criteria can be evaluated, such
as heat-up speed, reaching the setpoint in the specified time, cooling of the heating element, etc.
RES-5007
17
Max. 5 mA
GND
Actual value-
Output
0…10 VDC
-
+
0…10 VDC
Temperature
display
e.g. ATR-x
0 V
13
0 - 300 °C range
2
3
4
5
6
7
8
9 10
300
Te
m
p
er
at
u
re
T
°C
VDC
Voltage U
60
90
120
150
180
210
240
270
1
20 ºC
“ZERO“
0.66 V
0 - 500 °C range
2
3
4
5
6
7
8
9 10
500
100
150
200
250
300
350
400
450
°C
VDC
Te
m
p
er
at
u
re
T
Voltage U
1
0 4 V
.
20 ºC
“ZERO“