Controller functions
Page 24
RES-420
curve, in other words it must not jump abruptly, fluc-
tuate or deviate temporarily in the wrong direction.
This kind of behavior would indicate that the U
R
measuring wire has been laid incorrectly.
If an error code is displayed, please proceed as
described in section 10.24 "Fault areas and causes"
on page 44.
11.Burn in the heatsealing band (
aling band“ auf Seite 22) and repeat the AUTOCAL
function.
9.5.2
Restart after replacing the heatse-
aling band
To replace the heatsealing band, proceed as described
in Kap. 9.4 „Heatsealing band“ auf Seite 22.
Always use a heatsealing band with the cor-
rect alloy, dimensions and copper-plating in
order to avoid malfunctions and overheating.
Continue with section 9.5.1, steps 9 and 10.
10
Controller functions
See also Kap. 8.6 „Wiring diagram (standard)“ auf
Seite 16.
10.1
Indicators and controls
The controller is now
ready
!
ENTER
HAND
RESET
ROPEX
RESISTRON
RES-4
"MENU" key for advancing to next menu step
or switching menu
< 1 sec. Press: Next menu step
1-2 sec. Press: Return to previous position
> 2 sec. Press (Hold):
Return to home position
(as of SW-Revision 100):
"ENTER" key
ENTER function:
HAND function:
RESET function:
Save values
Manual mode
Reset after alarm
"UP" and "DOWN" keys for setting values
Press (< 2 sec.): Slow change
Hold (> 2 sec.): Fast change
LC display, 4 lines, multilingual
isplay, 4 lines, multilingual
optional:
VF d