Controller functions
Page 32
RES-409
Version 1
10.3
Receiving CAN messages
The complete command set of the RES-409 is shown in the table below:
Address
(hex)
Value
(dec)
Meaning
0000
0001
0002
0003
0100
0101
0102
0103
0…T
max
0…T
max
0…T
max
0…T
max
0…T
max
0…T
max
0…T
max
0…T
max
Store set point 0 (in °C)
Store set point 1 (in °C)
Store set point 2 (in °C)
Store set point 3 (in °C)
As of February 2007:
Temporarily overwrite set point 0 (in °C)
Temporarily overwrite set point 1 (in °C)
Temporarily overwrite set point 2 (in °C)
Temporarily overwrite set point 3 (in °C)
0004
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
256
257
258
259
Query set point 0 (in °C)
Query set point 1 (in °C)
Query set point 2 (in °C)
Query set point 3 (in °C)
Query controller status
Run "AUTOCAL" function
Run "Reset" after fault
Query current actual value
Query controller number, part 1
Query controller number, part 2
Query calibration temperature
Query current upper temperature monitoring value (see value 22)
Query current value of heatsealing band alloy/temperature range
As of February 2007:
Query current fault and AUTOCAL status
Query current hold mode setting
Query current "AUTOCOMP" status
Query maximum set point
Query current software revision
Query current software version (default value: 00)
Query current variable temperature coefficient (TCR in ppm/K)
Query current configuration of "Temperature OK" bit
Query current lower temperature monitoring value
Query current upper temperature monitoring value
Query current configuration of temperature diagnosis
Query current value of temperature diagnosis delay (in 0.1s units)
Query current configuration of heatup timeout (in 0.1s units)
Query current value of measuring impulse length (in 0.1s units)
Query current value of temperature range
Query current controller type (as of software revision 102)
Preset temporary set point 0 to stored set point 0
Preset temporary set point 1 to stored set point 1
Preset temporary set point 2 to stored set point 2
Preset temporary set point 3 to stored set point 3