Technical data
Page 12
RES-409
Version 1
Heatsealing band
type and temperature
range
All controllers manufactured as of February 2007:
The temperature range and temperature coefficient settings can also be specified
in the ROPEX visualization software (
section 10.12 "Diagnostic interface /
visualization software (as of February 2007)" on page 50) in addition to using the
rotary coding switch (see below) or the CAN interface:
Temperature range:
200°C, 300°C, 400°C or 500°C
Temperature coefficient: 400…4000ppm (variable setting range)
Five different ranges can be set with the rotary coding switch:
Temperature coefficient 1100ppm, 0…300°C (e.g. Alloy A20)
Temperature coefficient 780ppm, 0…300°C (e.g. Alloy L)
Temperature coefficient 1100ppm, 0…500°C (e.g. Alloy A20)
Temperature coefficient 780ppm, 0…500°C (e.g. Alloy L)
Temperature coefficient 3500ppm, 0…300°C (e.g. LEX3500)
Various ranges can be selected via the CAN interface:
Temperature coefficient 1100ppm (e.g. Alloy A20)
0…200°C, 0…300°C, 0…400°C, 0…500°C
Temperature coefficient 780ppm (e.g. Alloy L)
0…200°C, 0…300°C, 0…400°C, 0…500°C
Temperature coefficient 3500ppm (e.g. LEX3500)
0…200°C, 0…300°C, 0…400°C, 0…500°C
All controllers manufactured as of February 2007:
The settings with the rotary coding switch are considered to be the
factory setting. This corresponds to CAN message address 8, value 10 (dec)
(
section 10.3 "Receiving CAN messages" on page 32).
All controllers manufactured up to January 2007:
Six different ranges can be set via the CAN interface:
Temperature coefficient 1100ppm, 0…200°C (e.g. Alloy A20)
Temperature coefficient 1100ppm, 0…300°C (e.g. Alloy A20)
Temperature coefficient 1100ppm, 0…400°C (e.g. Alloy A20)
Temperature coefficient 1100ppm, 0…500°C (e.g. Alloy A20)
Temperature coefficient 3500ppm, 0…200°C (e.g. LEX3500)
Temperature coefficient 3500ppm, 0…300°C (e.g. LEX3500)
Analog output
(actual value)
Terminals 17+18
0…10V DC, Imax = 5mA
Equivalent to 0…300°C or 0…500°C
Accuracy: ±1% add. 50mV
Digital logic levels
Terminals 5, 7
(As of February 2007)
LOW (0V): 0…2VDC, electrically isolated
HIGH (24VDC): 12…30VDC (max. current input 6mA)
Reverse polarity-protected
Alarm relay
Terminals 12, 13, 14
U
max
= 30V (DC/AC), I
max
= 0.2A, changeover contact, potential-free
Maximum load
(primary current of
impulse
transformer)
I
max
= 5A (duty cycle = 100%)
I
max
= 25A (duty cycle = 20%)
Power dissipation
max. 20W
!